COINCIDENCE IN HIGH-SPEED FLOW-CYTOMETRY - MODELS AND MEASUREMENTS

被引:23
作者
KEIJ, JF
VANROTTERDAM, A
GROENEWEGEN, AC
STOKDIJK, W
VISSER, JWM
机构
[1] Institute of Applied Radiobiology and Immunology Tno, Rijswijk
来源
CYTOMETRY | 1991年 / 12卷 / 05期
关键词
CELL SORTING; POISSON; SIMULATION; ZAPPER;
D O I
10.1002/cyto.990120504
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In flow cytometry, the coincident arrival of particles becomes a major problem when high sample rates are required. For the development of our high-speed photodamage flow cytometer (ZAPPER), it was of importance to understand the behavior of cells at flow rates of around 50,000-250,000 event/s. We developed and compared two models that describe the relation between the real cell rate and the detectable single cell rate. Both the Computer Simulation model and the Input/ Output Device model show distinct optima for the cell rate. The models were compared to measurements performed on the ZAPPER-prototype. Fits of the two models to the experimental data were excellent for cycle times of 4 and 15-mu-s and acceptable for a 2-mu-s cycle time. A third model (Mercer WB, Rev. Sci. Instr. 37:1515-1521,1966) could be fitted to the experimental data, after the proportionality constant k was adapted to the experimental data. At a yield of detectable single cells of 70%, the maximum cell rates are 180,000, 100,000, and 40,000 cells/s for cycle times of 2, 4, and 15-mu-s, respectively. Based on these results we can now select an optimal cell rate for analysis and sorting based on criteria such as accepted cell loss. In addition, the advantages of reducing the cycle time can now be evaluated with respect to the costs of that modification.
引用
收藏
页码:398 / 404
页数:7
相关论文
共 11 条
[1]  
ASHCROFT B, 1987, CYTOMETRY S, V1, P104
[2]  
FRIEDMAN M, 1974, Patent No. 3791517
[3]   ELECTRONIC SEPARATION OF BIOLOGICAL CELLS BY VOLUME [J].
FULWYLER, MJ .
SCIENCE, 1965, 150 (3698) :910-&
[4]   HIGH-SPEED PHOTODAMAGE CELL SELECTION USING BROMODEOXYURIDINE HOECHST-33342 PHOTOSENSITIZED CELL KILLING [J].
HERWEIJER, H ;
STOKDIJK, W ;
VISSER, JWM .
CYTOMETRY, 1988, 9 (02) :143-149
[5]   SPECTROPHOTOMETRIC CELL SORTER [J].
KAMENTSKY, LA ;
MELAMED, MR .
SCIENCE, 1967, 156 (3780) :1364-+
[6]   MEASUREMENT OF THE DISTRIBUTION OF TIME INTERVALS BETWEEN CELL PASSAGES IN FLOW-CYTOMETRY AS A METHOD FOR THE EVALUATION OF SAMPLE PREPARATION PROCEDURES [J].
LINDMO, T ;
FUNDINGSRUD, K .
CYTOMETRY, 1981, 2 (03) :151-154
[7]  
MARTIN JC, 1981, CYTOMETRY, V2, P114
[8]  
MERCER WB, 1966, REV SCI INSTRUM, V37, P151
[9]   THE LLNL HIGH-SPEED SORTER - DESIGN-FEATURES, OPERATIONAL CHARACTERISTICS, AND BIOLOGICAL UTILITY [J].
PETERS, D ;
BRANSCOMB, E ;
DEAN, P ;
MERRILL, T ;
PINKEL, D ;
VANDILLA, M ;
GRAY, JW .
CYTOMETRY, 1985, 6 (04) :290-301
[10]  
SHAPIRO HM, 1983, Patent No. 4395397