OZONE IN THE URBAN SOUTHEASTERN UNITED-STATES

被引:11
作者
ANEJA, VP
YODER, GT
ARYA, SP
机构
[1] Department of Marine, Earth and Atmospheric Sciences, North Carolina State University, Raleigh
关键词
D O I
10.1016/0269-7491(92)90054-E
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ozone measurements (daily maximum values) from the Aerometric Information Retrieval System database are analyzed for selected sites, during 1980 to 1988. in southeastern USA. Frequency distributions, for most sites during most years. show a typical bell-shaped curve with the higher frequency around the yearly daily maximum ozone mean of about 100 to about 110-mu-g m-3 (50-55 ppbv). Abnormal years in ozone concentration may skew the distribution as the mean shifts. A correlation of daily maximum ozone concentrations above 140-mu-g m-3 (70 ppbv) between sites shows a division between the sites in the northern portion of the region and those in the southern portion of the region. Variations in ozone levels are well correlated over distances of several hundred kilometers, suggesting that high values are associated with synoptic scale episodes. An ozone exposure analysis also shows higher ozone exposures (250-300 ppm days) in the northerly sites as compared to the southerly sites (150-170 ppm days).
引用
收藏
页码:39 / 44
页数:6
相关论文
共 17 条