MINIMAL MODELS OF GLUCOSE DISAPPEARANCE - LESSONS FROM THE LABELED IVGTT

被引:49
作者
CAUMO, A [1 ]
GIACCA, A [1 ]
MORGESE, M [1 ]
POZZA, G [1 ]
MICOSSI, P [1 ]
COBELLI, C [1 ]
机构
[1] UNIV PADUA,DEPT ELECTR & INFORMAT,VIA GRADENIGO 6A,I-35100 PADUA,ITALY
关键词
IVGTT; MATHEMATICAL MODEL; INSULIN SENSITIVITY; GLUCOSE CLEARANCE;
D O I
10.1111/j.1464-5491.1991.tb02120.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this paper the domain of validity of the unlabelled and labelled minimal models of glucose disappearance is studied. Labelled intravenous glucose tolerance tests were performed in six normal subjects using 3-H-3-glucose as the tracer. Insulin and unlabelled glucose data were analysed with the minimal model of glucose disappearance. The model provides estimates of glucose effectiveness (S(G)) and insulin sensitivity (S(l)) which measure the effects of glucose per se and insulin on both glucose production and disposal. Insulin and labelled glucose data were analysed with the labelled minimal model of tracer disappearance. Estimates of glucose effectiveness (S(G)*) and insulin sensitivity (S(l)*) which reflect disposal processes only were calculated. The results of the two minimal models suggest two areas of model error. Firstly, the relationships between labelled and unlabelled parameters contradict the theoretical expectation. Secondly, the time-course of hepatic glucose production is unrealistic. Possible sources of these inconsistencies are an inadequate description of the glucose and/or insulin effect upon hepatic glucose production, and the assumption that glucose kinetics are monocompartmental. The monocompartmental description of glucose kinetics may affect both model parameters and hepatic glucose production and this leads to a critical reexamination of the previously published validation studies in which the minimal model metabolic indices have been compared with the analogous indices measured during glucose clamp studies.
引用
收藏
页码:822 / 832
页数:11
相关论文
共 20 条
[1]  
Bergman RN, Ider YZ, Bowden CR, Cobelli C, Quantitative estimation of insulin sensitivity, Am J Physiol, 236, (1979)
[2]  
Bergman RN, Cobelli C, Minimal modeling, partition analysis, and the estimation of insulin sensitivity, Fed Proc, 39, pp. 110-115, (1980)
[3]  
Bergman RN, Phillips NLS, Cobelli C, Physiologic evaluation of factors controlling glucose tolerance in man. Measurement of insulin sensitivity and β‐cell glucose sensitivity from the response to intravenous glucose, J Clin Invest, 68, pp. 1456-1467, (1981)
[4]  
Cobelli C, Pacini G, Toffolo G, Sacca L, Estimation of insulin sensitivity and glucose clearance from minimal model: new insights from labeled IVGTT, Am J Physiol, 250, (1986)
[5]  
Avogaro A, Bristow JD, Bier DM, Cobelli C, Toffolo G, Stable‐label intravenous glucose tolerance test minimal model, Diabetes, 38, pp. 1048-1055, (1989)
[6]  
Somogyi M, Determination of blood sugars, J Biol Chem, 160, pp. 68-73, (1945)
[7]  
Carson ER, Cobelli C, Finkelstein L, The Mathematical Modeling of Metabolic and Endocrine Systems, (1983)
[8]  
Fletcher R, A Modified Marquardt Subroutine for Nonlinear Least Squares, Atomic Energy Research Establishment Report R AERE‐R 6799, (1971)
[9]  
Cherrington AD, Williams PE, Harris MS, Relationship between the plasma glucose level and glucose uptake in the conscious dog, Metabolism, 27, pp. 787-791, (1978)
[10]  
Bell PM, Firth RG, Rizza RA, Effects of hyperglycaemia on glucose production and utilization in humans. Measurement with [2‐<sup>3</sup>H]‐, [3‐<sup>3</sup>H]‐, [6‐<sup>14</sup>C]‐glucose, Diabetes, 35, pp. 642-648, (1986)