QUANTITATIVE-ANALYSIS OF ELASTIC RECOIL AFTER BALLOON ANGIOPLASTY AND AFTER INTRACORONARY IMPLANTATION OF BALLOON-EXPANDABLE PALMAZ-SCHATZ STENTS

被引:172
作者
HAUDE, M
ERBEL, R
ISSA, H
MEYER, J
机构
[1] 2nd Medical Clinic, Johannes Gutenberg University, Mainz
关键词
D O I
10.1016/0735-1097(93)90713-B
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The purpose of this study was to measure elastic recoil from sequential angiograms after balloon angioplasty and after implantation of a balloon-expandable Palmaz-Schatz stent in the same patient, and to compare the results with the late angiographic outcome. Background. The immediate result of coronary balloon angioplasty is influenced by plastic deformation, primarily of the atherosclerotic plaque, and by elastic recoil, primarily of the less or nondiseased vessel circumference. Methods. The extent of elastic recoil was measured quantitatively as the difference between maximal balloon size and the resulting vessel diameter or cross-sectional area. Results. Analysis was performed in 60 patients who received a single stent for late restenosis after initially successful coronary balloon angioplasty. Minimal lumen diameter (minimal cross-sectional area) was 0.98 +/- 0.43 mm (0.97 +/- 0.67 mm2) before balloon angioplasty, 2.06 +/- 0.36 mm (3.68 +/- 1.17 mm2) after angioplasty (both p < 0.001 vs. values before angioplasty) and 2.98 +/- 0.26 mm (7.12 +/- 1.28 mm2) after stenting (both p < 0.001 vs. postangioplasty results). No significant changes in vessel reference diameters or areas were measured. Mean balloon/artery ratios were similar in both procedures, ranging from 0.93 to 0.96. The calculated mean elastic recoil was 0.98 +/- 0.50 mm in diameter (31%) and 3.67 +/- 2.05 mm2 in area (48%) after balloon angioplasty compared with 0.10 +/- 0.07 mm (3.5%) and 0.38 +/-0.36 mm2 (5.1%) after stenting. Increasing balloon sizes induced increased vessel stretch, which was followed by increased elastic recoil in the angioplasty group in contrast to the stenting group. Short, noncalcified and eccentric lesions tend to be associated with increased recoil after balloon angioplasty. Overdilation or under-dilation in one of the procedures, changes in postprocedural vasomotion or postprocedural thrombus formation was not responsible for this outcome. After 6 months mean minimal lumen diameter was 2.39 +/- 0.58 mm, suggesting a mean hyperplasia of 0.59 +/- 0.51 mm. Twelve patients (20%) had a follow-up diameter thal was equal to or less than the mean postangioplasty result and eight patients (14%) had a diameter stenosis of >50%. Conclusions. The implantation of a Palmaz-Schatz stent almost completely eliminates the decrease in vessel dimensions caused by elastic recoil and therefore diminishes the impact of hyperplasia and reduces the rate of restenosis.
引用
收藏
页码:26 / 34
页数:9
相关论文
共 47 条
  • [1] TRANS-LUMINAL CORONARY ANGIOPLASTY OF POSTMORTEM HUMAN HEARTS
    BAUGHMAN, KL
    PASTERNAK, RC
    FALLON, JT
    BLOCK, PC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (06) : 1044 - 1047
  • [2] BEATT K J, 1989, Journal of the American College of Cardiology, V13, p224A
  • [3] TRANS-LUMINAL ANGIOPLASTY - CORRELATION OF MORPHOLOGIC AND ANGIOGRAPHIC FINDINGS IN AN EXPERIMENTAL-MODEL
    BLOCK, PC
    BAUGHMAN, KL
    PASTERNAK, RC
    FALLON, JT
    [J]. CIRCULATION, 1980, 61 (04) : 778 - 785
  • [4] MORPHOLOGY AFTER TRANS-LUMINAL ANGIOPLASTY IN HUMAN-BEINGS
    BLOCK, PC
    MYLER, RK
    STERTZER, S
    FALLON, JT
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1981, 305 (07) : 382 - 385
  • [5] BLOCK PC, 1980, DHEW NIH802030 PUB, P155
  • [6] QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION
    BROWN, BG
    BOLSON, E
    FRIMER, M
    DODGE, HT
    [J]. CIRCULATION, 1977, 55 (02) : 329 - 337
  • [7] THE MECHANISM OF BALLOON ANGIOPLASTY
    CASTANEDAZUNIGA, WR
    FORMANEK, A
    TADAVARTHY, M
    VLODAVER, Z
    EDWARDS, JE
    ZOLLIKOFER, C
    AMPLATZ, K
    [J]. RADIOLOGY, 1980, 135 (03) : 565 - 571
  • [8] PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - 10 YEARS EXPERIENCE
    CHOKSHI, SK
    MEYERS, S
    ABIMANSOUR, P
    [J]. PROGRESS IN CARDIOVASCULAR DISEASES, 1987, 30 (03) : 147 - 210
  • [9] EMERGENCY STENTING FOR REFRACTORY ACUTE CORONARY-ARTERY OCCLUSION DURING CORONARY ANGIOPLASTY
    DEFEYTER, PJ
    DESCHEERDER, I
    VANDENBRAND, M
    LAARMAN, GJ
    SURYAPRANATA, H
    SERRUYS, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (15) : 1147 - 1150
  • [10] DOBIN PB, 1969, AM J PHYSIOL, V217, P1644