MEASUREMENT OF EPIDOXORUBICIN AND ITS METABOLITES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AN ADVANCED AUTOMATED SAMPLE PROCESSOR

被引:16
作者
DOBBS, NA
TWELVES, CJ
机构
[1] Imperial Cancer Research Fund, Clinical Oncology Unit, United Medical and Dental Schools, London, SE1 9RT, St. Thomas' Street
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1991年 / 572卷 / 1-2期
关键词
D O I
10.1016/0378-4347(91)80485-U
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and rapid method for measuring epidoxorubicin and its six metabolites by high-performance liquid chromatography using an advanced automated sample processor is described. Plasma samples (1 ml) were extracted using C2 cassettes, and reversed-phase chromatography was performed with an Apex II ODS column. The isocratic mobile phase of acetonitrile-0.019 M NaH2PO4 (pH 4.0) had a flow-rate of 1 ml/min and the fluorescence detector an excitation wavelength of 480 nm with an emission at 580 nm. Linear calibration curves were obtained which were reproducible both within-day and day-to-day (coefficients of variation < 10%). The extraction efficacy of epidoxorubicin was 88% and ranged from 51 to 88% for the metabolites. This method has been successfully applied to measure the plasma levels of these compounds in patients receiving epidoxorubicin over a wide dose range (12-120 mg/m2) and in patients with disturbed liver biochemistry.
引用
收藏
页码:211 / 217
页数:7
相关论文
共 11 条
  • [1] SYNTHESIS AND ANTITUMOR PROPERTIES OF NEW GLYCOSIDES OF DAUNOMYCINONE AND ADRIAMYCINONE
    ARCAMONE, F
    PENCO, S
    VIGEVANI, A
    REDAELLI, S
    FRANCHI, G
    DIMARCO, A
    CASAZZA, AM
    DASDIA, T
    FORMELLI, F
    NECCO, A
    SORANZO, C
    [J]. JOURNAL OF MEDICINAL CHEMISTRY, 1975, 18 (07) : 703 - 707
  • [2] CAMAGGI CM, 1988, CANCER CHEMOTH PHARM, V21, P216
  • [3] CAMAGGI CM, 1988, CANCER CHEMOTH PHARM, V21, P221
  • [4] CASPER ES, 1987, CLIN TRIALS J, V24, P57
  • [5] DEESEN PE, 1984, DRUG METAB DISPOS, V12, P9
  • [6] RAPID QUANTITATIVE-DETERMINATION OF EPIRUBICIN AND ITS METABOLITES IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND FLUORESCENCE DETECTION
    DINE, T
    BRUNET, C
    LUYCKX, M
    CAZIN, M
    GOSSELIN, P
    CAZIN, JL
    [J]. BIOMEDICAL CHROMATOGRAPHY, 1990, 4 (01) : 20 - 23
  • [7] GANZINA F, 1979, CANCER TREAT REV, V10, P1
  • [8] IMPROVED METHOD FOR THE DETERMINATION OF 4'-EPIDOXORUBICIN AND 7 METABOLITES IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MAESSEN, PA
    MROSS, KB
    PINEDO, HM
    VANDERVIJGH, WJF
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 417 (02): : 339 - 346
  • [9] NERI B, 1989, INT J CLIN PHARM TH, V27, P217
  • [10] TWELVES C, 1990, BRIT J CANCER, V62, P528