COMPARISON OF OPTICAL, NEEDLE PROBE AND ULTRASONIC TECHNIQUES FOR THE MEASUREMENT OF ARTICULAR-CARTILAGE THICKNESS

被引:141
作者
JURVELIN, JS
RASANEN, T
KOLMONEN, P
LYYRA, T
机构
[1] UNIV KUOPIO,DEPT ANAT,SF-70211 KUOPIO,FINLAND
[2] KUOPIO UNIV HOSP,DEPT CLIN PHYSIOL,SF-70210 KUOPIO,FINLAND
[3] UNIV KUOPIO,DEPT APPL PHYS,SF-70211 KUOPIO,FINLAND
关键词
D O I
10.1016/0021-9290(94)00060-H
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Analysis of the mechanical properties of articular cartilage necessitates determination of thickness of the tested tissue. Tb evaluate the suitability of different methods for thickness measurements, the thickness of bovine and canine knee articular cartilage was determined with optical (stereomicroscopic), needle probe and ultrasonic techniques. The results obtained with the stereomicroscope and the needle probe showed high, linear correlations (r=0.97, n=80). The mean thickness obtained with the needle was slightly higher than the optical thickness (0.88+/-0.36mm vs 0.85+/-0.34mm, mean+/-S.D., n=80, p<0.01, matched-pairs Student t-test) or the ultrasonic thickness (0.93+/-0.42mm vs 0.87+/-0.36mm, n=45, p<0.05). The high scatter between optical and ultrasonic thickness, considered to be due to complex measurement geometry of canine knee articular cartilage, invaliditated the use of the A-mode, 10 MHz-ultrasonic device for thickness measurements, Based on the results of uncertainty analysis it is concluded that optical and needle probe methods can be used interchangeably when determining shear modulus of articular cartilage with indentation tests. However, if high area-aspect ratios (indenter radius-to-cartilage thickness ratios) are used in the indentation measurements uncertainty in shear modulus may be markedly increased due to possible errors in the measurement of cartilage thickness.
引用
收藏
页码:231 / 235
页数:5
相关论文
共 19 条
  • [1] ASME MEASUREMENT UNCERTAINTY
    ABERNETHY, RB
    BENEDICT, RP
    DOWDELL, RB
    [J]. JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (02): : 161 - 164
  • [2] INTERSPECIES COMPARISONS OF INSITU INTRINSIC MECHANICAL-PROPERTIES OF DISTAL FEMORAL CARTILAGE
    ATHANASIOU, KA
    ROSENWASSER, MP
    BUCKWALTER, JA
    MALININ, TI
    MOW, VC
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (03) : 330 - 340
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] SPEED OF SOUND IN PURE WATER
    DELGROSS.VA
    MADER, CW
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1972, 52 (05) : 1442 - &
  • [5] MATHEMATICAL-ANALYSIS FOR INDENTATION TESTS OF ARTICULAR-CARTILAGE
    HAYES, WC
    HERRMANN, G
    MOCKROS, LF
    KEER, LM
    [J]. JOURNAL OF BIOMECHANICS, 1972, 5 (05) : 541 - &
  • [6] HOCH D H, 1983, Journal of Orthopaedic Research, V1, P4, DOI 10.1002/jor.1100010102
  • [7] JAECH JL, 1985, STATISTICAL ANAL MEA
  • [8] INDENTATION STIFFNESS OF YOUNG CANINE KNEE ARTICULAR-CARTILAGE - INFLUENCE OF STRENUOUS JOINT LOADING
    JURVELIN, J
    KIVIRANTA, I
    SAAMANEN, AM
    TAMMI, M
    HELMINEN, HJ
    [J]. JOURNAL OF BIOMECHANICS, 1990, 23 (12) : 1239 - 1246
  • [9] Indentation study of the biomechanical properties of articular cartilage in the canine knee
    Jurvelin, J.
    Kiviranta, I.
    Arokoski, J.
    [J]. Engineering in Medicine, 1987, 16 (01): : 15 - 22
  • [10] TECHNIQUE FOR PREPARATION OF PLUGS OF ARTICULAR-CARTILAGE AND SUBCHONDRAL BONE
    LIPSHITZ, H
    GLIMCHER, MJ
    [J]. JOURNAL OF BIOMECHANICS, 1974, 7 (03) : 293 - &