THE THERMODILUTION METHOD FOR THE CLINICAL-ASSESSMENT OF CARDIAC-OUTPUT

被引:69
作者
JANSEN, JRC
机构
[1] Department of Pulmonary Diseases, Erasmus University, DR Rotterdam, NL-3000, Room
关键词
D O I
10.1007/BF01711553
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The thermodilution technique has been shown to measure cardiac output accurately if flow is stationary. During mechanical ventilation the technique can be liable to gross errors. However, if certain precautions are followed mean cardiac output can be accurately estimated, even with a theoretical misuse of the Stewart-Hamilton equation. This can be done best by averaging three or four measurements equally spread over the ventilatory cycle. For this approach manufacturers of cardiac output computers have to be persuaded to include a phase selector and an automatic injector. © 1995 Springer-Verlag.
引用
收藏
页码:691 / 697
页数:7
相关论文
共 44 条
[1]   FLOW ESTIMATION BY INDICATOR DILUTION (BOLUS-INJECTION) - REDUCTION OF ERRORS DUE TO TIME-AVERAGED SAMPLING DURING UNSTEADY FLOW [J].
BASSINGTHWAIGHTE, JB ;
KNOPP, TJ ;
ANDERSON, DU .
CIRCULATION RESEARCH, 1970, 27 (02) :277-+
[2]   ERRORS IN THERMODILUTION CARDIAC-OUTPUT MEASUREMENTS CAUSED BY RAPID PULMONARY-ARTERY TEMPERATURE DECREASES AFTER CARDIOPULMONARY BYPASS [J].
BAZARAL, MG ;
PETRE, J ;
NOVOA, R .
ANESTHESIOLOGY, 1992, 77 (01) :31-37
[3]   A COMPLICATION WITH THERMODILUTION CARDIAC OUTPUTS IN CENTRALLY-PLACED PULMONARY-ARTERY CATHETERS [J].
BEARSS, MG ;
YONUTAS, DN ;
ALLEN, WT .
CHEST, 1982, 81 (04) :527-527
[4]   DETERMINATION OF HEAT GAIN IN THE INFERIOR VENA-CAVA DURING THERMODILUTION MEASUREMENTS [J].
BRYANT, GH ;
CUCINELL, SA ;
BARCIA, PJ .
JOURNAL OF SURGICAL RESEARCH, 1985, 39 (03) :224-229
[5]   EVALUATION OF THE STERILITY OF THERMODILUTION ROOM-TEMPERATURE INJECTATE PREPARATIONS [J].
BURKE, KG ;
LARSON, E ;
MACIOROWSKI, L ;
ADLER, DC .
CRITICAL CARE MEDICINE, 1986, 14 (05) :503-504
[6]   UNDERESTIMATION OF CARDIAC-OUTPUT BY THERMODILUTION IN PATIENTS WITH TRICUSPID REGURGITATION [J].
CIGARROA, RG ;
LANGE, RA ;
WILLIAMS, RH ;
BEDOTTO, JB ;
HILLIS, LD .
AMERICAN JOURNAL OF MEDICINE, 1989, 86 (04) :417-420
[7]   THE MEASUREMENT OF RIGHT VENTRICULAR EJECTION FRACTION BY THERMODILUTION - A COMPARISON OF VALUES OBTAINED USING DIFFERING INJECTATE PORTS [J].
COCKROFT, S ;
WITHINGTON, PS .
ANAESTHESIA, 1993, 48 (04) :312-314
[8]   CARDIAC-OUTPUT BY THERMODILUTION TECHNIQUE - EFFECT OF INJECTATES VOLUME AND TEMPERATURE ON ACCURACY AND REPRODUCIBILITY IN THE CRITICALLY ILL PATIENT [J].
ELKAYAM, U ;
BERKLEY, R ;
AZEN, S ;
WEBER, L ;
GEVA, B ;
HENRY, WL .
CHEST, 1983, 84 (04) :418-422
[9]   MEASUREMENT OF CARDIAC OUTPUT IN ANAESTHETIZED ANIMALS BY A THERMO-DILUTION METHOD [J].
FEGLER, G .
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES, 1954, 39 (03) :153-164
[10]   SEMINAR ON CLINICAL APPLICATION OF TECHNIQUES TO MEASURE BLOOD-FLOW IN MAN .2. MEASUREMENT OF BLOOD-FLOW BY THERMODILUTION [J].
GANZ, W ;
SWAN, HJC .
AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (02) :241-+