IN-VITRO EVALUATION OF THE EFFICACY AND BIOCOMPATIBILITY OF NEW, SYNTHETIC ABO IMMUNOABSORBENTS

被引:33
作者
RIEBEN, R
KORCHAGINA, EY
VONALLMEN, E
HOVINGA, JK
LAMMLE, B
JUNGI, TW
BOVIN, NV
NYDEGGER, UE
机构
[1] UNIV BERN,CENT HEMATOL LAB,CH-3010 BERN,SWITZERLAND
[2] UNIV BERN,REG RED CROSS,CTR BLOOD TRANSFUS,CH-3010 BERN,SWITZERLAND
[3] UNIV BERN,INST VET VIROL,CH-3010 BERN,SWITZERLAND
[4] RUSSIAN ACAD SCI,SHEMYAKIN & OVCHINNIKOV INST BIOORGAN CHEM,MOSCOW,RUSSIA
关键词
D O I
10.1097/00007890-199509000-00004
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Synthetic ABO immunoabsorbents (known as Synsorbs(R)) were in use for several years to specifically eliminate ABO antibodies from the patient's circulation before ABO-incompatible organ or bone marrow transplantation. Because Synsorbs are no longer available, we have developed new ABO immunoabsorbents, These substances, termed BioSorbents A and B, respectively, consist of synthetic A or B trisaccharides covalently coupled to macroporous glass beads via polyacrylamide, Here we report the evaluation of BioSorbents in regard to efficacy, specificity, and biocompatibility, Using a closed-circuit in vitro system, representing a 1:10-1:20 scale as compared with the immunoabsorption procedure with an adult patient, blood group O plasma was run through columns filled with ethylene oxide-sterilized BioSorbent, Hemagglutination was reduced by 4 titer steps after absorption, and anti-A and/or anti-B IgM/G/A, as measured by ABO ELISA, dropped by 85% or more, while no nonspecific absorption of immunoglobulins occurred. No significant changes could be observed for complement (C3, C4, and total hemolytic complement of the classical pathway) or for coagulation parameters (fibrinogen, prothrombin time, activated partial thromboplastin time), As monitored by immunoblotting, neither factor XII nor high molecular weight kininogen was cleaved, In addition, a monocyte phagocytosis inhibition test provided evidence that no significant aggregation of IgG had occurred during absorption. We conclude that BioSorbents A and B are efficient, specific, and biocompatible with human plasma.
引用
收藏
页码:425 / 430
页数:6
相关论文
共 28 条
[1]  
AESCHBACHER B, 1987, SCHWEIZ MED WSCHR, V117, P716
[2]  
AGISHI T, 1992, TRANSPLANT P, V24, P557
[3]  
BANNETT AD, 1987, TRANSPLANT P, V19, P4543
[4]  
BENSINGER W, 1989, BONE MARROW TRANSPL, V4, P409
[5]   INVITRO AND INVIVO REMOVAL OF ANTI-A ERYTHROCYTE ANTIBODY BY ADSORPTION TO A SYNTHETIC IMMUNOADSORBENT [J].
BENSINGER, WI ;
BAKER, DA ;
BUCKNER, CD ;
CLIFT, RA ;
THOMAS, ED .
TRANSFUSION, 1981, 21 (03) :335-342
[6]   ABO-INCOMPATIBLE BONE-MARROW TRANSPLANTATION PREPARATION BY PLASMA EXCHANGE AND INVIVO ANTIBODY ABSORPTION [J].
BERKMAN, EM ;
CAPLAN, S ;
KIM, CS .
TRANSFUSION, 1978, 18 (04) :504-508
[7]   IMPROVED REMOVAL OF ANTI-A AND ANTI-B ANTIBODIES FROM PLASMA USING BLOOD-GROUP-ACTIVE HAPTENS [J].
BLOMBERG, L ;
BRATT, T ;
CHESTER, MA ;
HANSSON, B .
VOX SANGUINIS, 1993, 65 (02) :126-135
[8]  
Bovin N. V., 1993, LECTINS GLYCOBIOLOGY, P23
[9]   SYNTHESIS OF POLYMERIC NEOGLYCOCONJUGATES BASED ON N-SUBSTITUTED POLYACRYLAMIDES [J].
BOVIN, NV ;
KORCHAGINA, EY ;
ZEMLYANUKHINA, TV ;
BYRAMOVA, NE ;
GALANINA, OE ;
ZEMLYAKOV, AE ;
IVANOV, AE ;
ZUBOV, VP ;
MOCHALOVA, LV .
GLYCOCONJUGATE JOURNAL, 1993, 10 (02) :142-151
[10]  
BUHLER R, 1955, BLOOD COAGUL FIBRIN, V6, P223