THRESHOLD CRITERIA USED FOR THE OPTIMIZATION OF SELECTIVITY BY TUNING INTERMEDIATE PRESSURE FOR SERIES-COUPLED COLUMNS IN A DUAL-OVEN SYSTEM

被引:15
作者
BENICKA, E
KRUPCIK, J
REPKA, D
KULJOVSKY, P
KAISER, RE
机构
[1] SLOVAK UNIV TECHNOL BRATISLAVA, FAC CHEM TECHNOL, DEPT ANALYT CHEM, RADINSKEHO 9, CS-81237 BRATISLAVA, CZECHOSLOVAKIA
[2] INST CHROMATOG, W-6702 BAD DURKHEIM 1, GERMANY
关键词
D O I
10.1021/ac00209a003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A computer-assisted procedure based on threshold criteria was employed for the optimization of selectivity by tuning the column coupling-point carrier gas pressure of two capillary columns of different polarities operated at different temperatures in a dual oven gas chromatograph using constant inlet and outlet carrier gas pressures. The optimization procedure was monitored by optimization criterion (Cp) calculated from the following equation: Cp= Σ1nmi + (tR.max - tR, n)/t R.max, where n is the number of solutes in a sample, mi= 1 if the resolution of peak pair is higher than a threshold, tR.maxIs the maximum acceptable analysis time, and tR, nis the last peak retention time. Three kinds of thresholds were compared in this paper: constant threshold; floating threshold predicted from the resolution factor; floating threshold predicted from the separation numbers. The use of a resolution factor calculated for each peak pair gave the best result. A comparable result was obtained by using the floating threshold. However, the last procedure was less tedious than the procedure based on the resolution factor. © 1990, American Chemical Society. All rights reserved.
引用
收藏
页码:985 / 990
页数:6
相关论文
共 14 条
[1]   GAS-CHROMATOGRAPHIC COLUMNS WITH ADJUSTABLE SEPARATION CHARACTERISTICS [J].
DEANS, DR ;
SCOTT, I .
ANALYTICAL CHEMISTRY, 1973, 45 (07) :1137-1141
[2]   EVALUATION OF CAPILLARY COLUMNS BY SEPARATION NUMBER OR PLATE NUMBER [J].
GROB, K ;
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1981, 207 (03) :291-297
[3]   SELECTIVITY TUNING OF SERIALLY CONNECTED OPEN-TUBULAR (CAPILLARY) COLUMNS IN GAS-CHROMATOGRAPHY .1. FUNDAMENTAL RELATIONSHIPS [J].
HINSHAW, JV ;
ETTRE, LS .
CHROMATOGRAPHIA, 1986, 21 (10) :561-572
[4]   SELECTIVITY TUNING OF SERIALLY CONNECTED OPEN-TUBULAR (CAPILLARY) COLUMNS IN GAS-CHROMATOGRAPHY .2. IMPLEMENTATION [J].
HINSHAW, JV ;
ETTRE, LS .
CHROMATOGRAPHIA, 1986, 21 (12) :669-680
[5]  
JENNINGS WG, 1978, GAS CHROMATOGRAPHY G, P70
[6]  
KAISER R, 1962, Z ANAL CHEM, V189, P1
[7]  
Kaiser R.E., 1985, HRC-J HIGH RES CHROM, V8, P92
[8]  
KAISER RE, 1979, HRC-J HIGH RES CHROM, V3, P416
[9]   CRITERIA FOR USE OF MIXED SOLVENTS IN GAS-LIQUID-CHROMATOGRAPHY [J].
LAUB, RJ ;
PURNELL, JH .
JOURNAL OF CHROMATOGRAPHY, 1975, 112 (OCT29) :71-79
[10]   OPTIMIZATION OF SELECTIVITY BY TUNING COLUMN TEMPERATURES FOR SERIES-COUPLED CAPILLARY COLUMNS IN DUAL-OVEN GAS-CHROMATOGRAPHIC SYSTEMS [J].
REPKA, D ;
KRUPCIK, J ;
BENICKA, E ;
LECLERCQ, PA ;
RIJKS, JA .
JOURNAL OF CHROMATOGRAPHY, 1989, 463 (02) :243-251