LAXITY AFTER CRUCIATE LIGAMENT INJURY IN 94 KNEES - THE KT-1000 ARTHROMETER VERSUS ROENTGEN STEREOPHOTOGRAMMETRY

被引:44
作者
JONSSON, H
KARRHOLM, J
ELMQVIST, LG
机构
[1] Department of Orthopedics, University Hospital of Northern Sweden, S-901 85, Umeå
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1993年 / 64卷 / 05期
关键词
D O I
10.3109/17453679308993694
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We examined 94 knees with chronic anterior cruciate ligament injuries, 55 of which had been operated with ligament reconstruction, using the KT-1000 arthrometer (89 N anterior force) and roentgen stereophotogmmmetry (RSA, 150 N anterior, 80 N posterior force). In intact knees the tibial displacement did not differ between the methods. In injured knees, operated or not, the KT-1000 recorded smaller AP translations and side-differences than RSA. Thus, the stabilizing effect of reconstructive surgery may be overrated, if evaluated with the standard KT-1000 technique
引用
收藏
页码:567 / 570
页数:4
相关论文
共 24 条
[1]   INSTRUMENTED EVALUATION OF KNEE LAXITY - A COMPARISON OF 5 ARTHROMETERS [J].
ANDERSON, AF ;
SNYDER, RB ;
FEDERSPIEL, CF ;
LIPSCOMB, AB ;
GRANA, WA .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1992, 20 (02) :135-140
[2]   ARTHROMETRIC EVALUATION OF KNEES THAT HAVE A TORN ANTERIOR CRUCIATE LIGAMENT [J].
BACH, BR ;
WARREN, RF ;
FLYNN, WM ;
KROLL, M ;
WICKIEWIECZ, TL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (09) :1299-1306
[3]   KNEE LAXITY IN CRUCIATE LIGAMENT INJURY - VALUE OF EXAMINATION UNDER ANESTHESIA [J].
DAHLSTEDT, LJ ;
DALEN, N .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (02) :181-184
[4]   INSTRUMENTED MEASUREMENT OF ANTERIOR LAXITY OF THE KNEE [J].
DANIEL, DM ;
MALCOM, LL ;
LOSSE, G ;
STONE, ML ;
SACHS, R ;
BURKS, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (05) :720-726
[5]   INSTRUMENTED MEASUREMENT OF ANTERIOR KNEE LAXITY IN PATIENTS WITH ACUTE ANTERIOR CRUCIATE LIGAMENT DISRUPTION [J].
DANIEL, DM ;
STONE, ML ;
SACHS, R ;
MALCOM, L .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1985, 13 (06) :401-407
[6]   ASSESSING THE LIMITS OF KNEE MOTION [J].
DANIEL, DM .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1991, 19 (02) :139-147
[7]   ACCURACY AND REPRODUCIBILITY OF INSTRUMENTED KNEE-DRAWER TESTS [J].
EDIXHOVEN, P ;
HUISKES, R ;
DEGRAAF, R ;
VANRENS, TJG ;
SLOOFF, TJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1987, 5 (03) :378-387
[8]  
EDIXHOVEN P, 1989, CLIN ORTHOP RELAT R, V247, P232
[9]   IS THE KT1000 KNEE LIGAMENT ARTHROMETER RELIABLE [J].
FORSTER, IW ;
WARRENSMITH, CD ;
TEW, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (05) :843-847
[10]   LAXITY AND GRAFT FIXATION AFTER RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT - A ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS OF 11 PATIENTS [J].
FRIDEN, T ;
RYD, L ;
LINDSTRAND, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1992, 63 (01) :80-84