SEM OBSERVATIONS ON STRESS-CORROSION CRACKING OF COMMERCIALLY PURE TITANIUM IN A TOPICAL FLUORIDE SOLUTION

被引:65
作者
KONONEN, MHO [1 ]
LAVONIUS, ET [1 ]
KIVILAHTI, JK [1 ]
机构
[1] HELSINKI UNIV TECHNOL,DEPT MAT SCI & ENGN,SF-02150 ESPOO,FINLAND
关键词
D O I
10.1016/0109-5641(95)80061-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The purpose of the present study was to determine whether commercially pure titanium is susceptible to stress corrosion cracking/ hydrogen embrittlement in a topical fluoride solution used in preventive dentistry. Methods. Thin electropolished titanium test specimens were previously cold-rolled or cold-rolled and annealed before testing. For the stress corrosion tests, the U-shaped specimens of both treatment types were stressed into a radius of curvature of 30 mm. Then, the bent part was placed in the fluoride solution at 37 degrees C for 1, 5, 10, and 20 d. The effects of the fluoride solution on cold-rolled and annealed titanium were studied using a scanning electron microscope. In addition, mechanically fractured surfaces of cold-rolled titanium specimens exposed and not exposed to the fluoride solution were examined by SEM. A qualitative evaluation of the surfaces was conducted. Results. Narrow cracks were observed in cold-rolled specimens following exposure to the fluoride solution for 5 d. The cracks were associated with branching, a characteristic of stress corrosion cracking. The cold-rolled specimen exposed to the fluoride solution exhibited a brittle fracture. In contrast, the fracture mode of the unexposed specimen was ductile in nature. Significance. Topical fluoride solutions can cause stress corrosion cracking of commercially pure titanium.
引用
收藏
页码:269 / 272
页数:4
相关论文
共 12 条
[1]  
BOSKER H, 1986, THESIS U UTRECHT NET, P1
[2]   A THERMODYNAMIC ANALYSIS OF THE TI-H SYSTEM [J].
KIVILAHTI, JK ;
MIETTINEN, JM .
CALPHAD-COMPUTER COUPLING OF PHASE DIAGRAMS AND THERMOCHEMISTRY, 1987, 11 (02) :187-199
[3]  
Lausmaa J., 1985, MATER RES SOC S P, V55, P351, DOI 10.1557/PROC-55-351
[4]   CORROSION BEHAVIOR AND USE OF TITANIUM AND ITS ALLOYS [J].
MYERS, JR ;
BOMBERGER, HB ;
FROES, FH .
JOURNAL OF METALS, 1984, 36 (10) :50-60
[5]  
PROBSTER L, 1992, INT J ORAL MAXILLOF, V7, P390
[6]   PREPARATION OF THIN FOILS FOR ELECTRON MICROSCOPY USING A CONTROLLED LOW TEMPERATURE TECHNIQUE [J].
RATY, R ;
LINDROOS, V ;
SAARINEN, A ;
FORSTEN, J ;
MIEKKOJA, HM .
JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (06) :367-&
[7]   AN OVERVIEW ON THE PASSIVITY OF METALS [J].
SATO, N .
CORROSION SCIENCE, 1990, 31 :1-19
[8]  
SCHUTZ RW, 1987, METALS HDB, P669
[9]  
Siirila H S, 1991, Int J Oral Maxillofac Implants, V6, P50
[10]  