POOLED PLATELET CONCENTRATES PREPARED BY THE PLATELET-RICH-PLASMA METHOD AND FILTERED WITH 3 DIFFERENT FILTERS AND STORED FOR 8 DAYS

被引:17
作者
BOOMGAARD, MN [1 ]
GOUWEROK, CWN [1 ]
PALFENIER, CH [1 ]
PANKALLABLANDEAU, IE [1 ]
VELDMAN, HA [1 ]
DEKORTE, D [1 ]
LOOS, JA [1 ]
机构
[1] NETHERLANDS RED CROSS,BLOOD TRANSFUS SERV,CENT LAB,1066 CX AMSTERDAM,NETHERLANDS
关键词
D O I
10.1111/j.1423-0410.1995.tb02558.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pooled platelet concentrates (PC) prepared by the platelet-rich plasma (PRP) method were filtered with three different filters and stored for 8 days at room temperature. The effect of filtration on leukocyte contamination, platelet concentration, and the in vitro function, morphology, metabolism and activation of platelets were studied. Eight pools of 20 PRP-PC were used, each pool was split into 4 equal volumes; 3 were filtered over a PL50HF, a PL-10A and a Bio P10 filter, the 4 served as a control. After filtration, leukocyte counts exceeded 3x10(5) in none of the pooled PC. Platelet loss induced by filtration was about 17%. During storage, no differences in pH, PCO2, and lactate and glucose concentration were found between the filtered and the unfiltered units, nor were any differences observed between filtered and unfiltered pooled PC in aggregation upon stimulation with collagen and/or ADP, adhesion capacity to collagen in flowing blood, nucleotide content of the platelets and nucleobase concentration in the plasma, expression of activation-dependent antigens, or platelet morphology as observed by light microscopy and by the swirling effect. Selective removal of beta-thromboglobulin (22%) by the PL50HF filter was observed. Pooled PC prepared by the PRP-method can be filtered and stored for 8 days without detrimental effect on platelet function, metabolism or activation.
引用
收藏
页码:82 / 89
页数:8
相关论文
共 32 条
[1]  
ANDREU G, 1988, BLOOD, V72, P964
[2]   COMPARISON OF PLATELET ACTIVATION AND MEMBRANE GLYCOPROTEIN-IB AND IIB-IIIA EXPRESSION AFTER FILTRATION THROUGH 3 DIFFERENT LEUKOCYTE REMOVAL FILTERS [J].
BERTOLINI, F ;
REBULLA, P ;
PORRETTI, L ;
SIRCHIA, G .
VOX SANGUINIS, 1990, 59 (04) :201-204
[3]   IN-VITRO EVALUATION OF PLATELET CONCENTRATES, PREPARED FROM POOLED BUFFY COATS, STORED FOR AND DAYS AFTER FILTRATION [J].
BOOMGAARD, MN ;
JOUSTRADIJKHUIS, AM ;
GOUWEROK, CWN ;
STENEKER, I ;
REESINK, HW ;
LOOS, JA ;
PIETERSZ, RNI ;
DEKORTE, D .
TRANSFUSION, 1994, 34 (04) :311-316
[4]   ANION-EXCHANGE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY METHOD FOR THE QUANTITATION OF NUCLEOTIDES IN HUMAN-BLOOD CELLS [J].
DEKORTE, D ;
HAVERKORT, WA ;
ROOS, D ;
VANGENNIP, AH .
CLINICA CHIMICA ACTA, 1985, 148 (03) :185-196
[5]  
DOLHOFER R, 1976, J CLIN CHEM CLIN BIO, V4, P415
[6]   INVITRO EVALUATION OF A HIGH-EFFICIENCY LEUKOCYTE ADHERENCE FILTER [J].
ELIAS, MK ;
SMIT, JW ;
WEGGEMANS, M ;
RIJSKAMP, L ;
CARPER, H ;
MCSHINE, RL ;
BRONS, R ;
PIETENS, J ;
HALIE, MR ;
SIBINGA, CTS .
ANNALS OF HEMATOLOGY, 1991, 63 (06) :302-306
[7]   PLATELET ACTIVATION DURING PREPARATION OF PLATELET CONCENTRATES - A COMPARISON OF THE PLATELET-RICH PLASMA AND THE BUFFY COAT METHODS [J].
FIJNHEER, R ;
PIETERSZ, RNI ;
DEKORTE, D ;
GOUWEROK, CWN ;
DEKKER, WJA ;
REESINK, HW ;
ROOS, D .
TRANSFUSION, 1990, 30 (07) :634-638
[8]   DETECTION OF PLATELET ACTIVATION WITH MONOCLONAL-ANTIBODIES AND FLOW-CYTOMETRY - CHANGES DURING PLATELET STORAGE [J].
FIJNHEER, R ;
MODDERMAN, PW ;
VELDMAN, H ;
OUWEHAND, WH ;
NIEUWENHUIS, HK ;
ROOS, D ;
DEKORTE, D .
TRANSFUSION, 1990, 30 (01) :20-25
[9]  
FIJNHEER R, 1991, VOX SANG, V60, P105
[10]   ALLOIMMUNIZATION TO HLA ANTIGENS FOLLOWING TRANSFUSION WITH LEUKOCYTE-POOR AND PURIFIED PLATELET SUSPENSIONS [J].
FISHER, M ;
CHAPMAN, JR ;
TING, A ;
MORRIS, PJ .
VOX SANGUINIS, 1985, 49 (05) :331-335