COMPARISON OF NUMERICAL-CALCULATIONS WITH PHANTOM EXPERIMENTS AND CLINICAL MEASUREMENTS

被引:14
作者
PAULSEN, KD
ROSS, MP
机构
[1] Department of Electrical and Computer Engineering, University of Arizona, Tucson
关键词
Clinical measurements; Numerical models; Phantom experiments; Treatment planning;
D O I
10.3109/02656739009141142
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Three-dimensional models, while fundamentally desirable in hyperthermia treatment simulation, are only beginning to emerge and may take a number of years to perfect for routine clinical use. Two dimensional calculations, on the other hand, can be efficiently performed on today's inexpensive computer workstations; however, the accuracy of two-dimensional models in the pretreatment planning context is questionable. This paper investigates the ability of a general two-dimensional finite element model to predict power deposition patterns in phantoms and temperature distributions during actual clinical treatments. The experiments and simulations have been performed for an annular phased array (APA) operating at 70 MHz. Comparisons between model predictions and measurements show that quantitative agreement occurs in phantoms containing moderate complexities in heterogeneity, but that only qualitative agreement appears possible in clinical treatments. However, the results suggest that the lack of blood flow information may contribute as much, if not more, to the uncertainties in the clinical predictions than the two-dimensional nature of the model itself. © 1990 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
引用
收藏
页码:333 / 349
页数:17
相关论文
共 37 条
[1]  
BAGSHAW MA, 1984, CANCER RES, V44, P4842
[2]   HEAT-TRANSPORT MECHANISMS IN VASCULAR TISSUES - A MODEL COMPARISON [J].
BAISH, JW ;
AYYASWAMY, PS ;
FOSTER, KR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (04) :324-331
[3]   PERFUSED PHANTOM MODELS OF MICROWAVE IRRADIATED TISSUE [J].
BAISH, JW ;
FOSTER, KR ;
AYYASWAMY, PS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (03) :239-245
[4]   SMALL-SCALE TEMPERATURE-FLUCTUATIONS IN PERFUSED TISSUE DURING LOCAL HYPERTHERMIA [J].
BAISH, JW ;
AYYASWAMY, PS ;
FOSTER, KR .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1986, 108 (03) :246-258
[5]  
CHARNY CK, 1988, ASME, V110, P277
[6]  
CHEN ZP, 1989, 37TH ANN M RAD RES S
[7]   CLINICAL-APPLICATION OF THERMAL ISOEFFECT DOSE [J].
DEWHIRST, MW ;
WINGET, JM ;
EDELSTEINKESHET, L ;
SYLVESTER, J ;
ENGLER, M ;
THRALL, DE ;
PAGE, RL ;
OLESON, JR .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1987, 3 (04) :307-318
[9]  
HAGMANN MJ, 1986, IEEE T BIOMEDICAL EN, V33, P874
[10]  
HORNSLETH SN, 1988, 5TH INT S HYP ONC KY