INTRAOPERATIVE ELECTRON-BEAM RADIATION-THERAPY - TECHNIQUE, DOSIMETRY, AND DOSE SPECIFICATION - REPORT OF TASK-FORCE 48 OF THE RADIATION-THERAPY COMMITTEE, AMERICAN-ASSOCIATION-OF-PHYSICISTS-IN-MEDICINE

被引:54
作者
PALTA, JR
BIGGS, PJ
HAZLE, JD
HUQ, MS
DAHL, RA
OCHRAN, TG
SOEN, J
DOBELBOWER, RR
MCCULLOUGH, EC
机构
[1] MASSACHUSETTS GEN HOSP,DEPT RADIAT MED,BOSTON,MA 02114
[2] UNIV TEXAS,MD ANDERSON CANC CTR,DEPT DIAGNOST RADIOL,HOUSTON,TX
[3] THOMAS JEFFERSON UNIV,DEPT RADIAT ONCOL,PHILADELPHIA,PA
[4] MAYO CLIN,ROCHESTER,MN
[5] PARIS REG CANC CTR,PARIS,TX
[6] HINSDALE HOSP,HINSDALE,IL
[7] MED COLL OHIO,DEPT RADIAT THERAPY,TOLEDO,OH 43699
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1995年 / 33卷 / 03期
关键词
RADIOTHERAPY; SURGERY; INTRAOPERATIVE CARE; ELECTRONS; NEOPLASMS;
D O I
10.1016/0360-3016(95)00280-C
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intraoperative radiation therapy (IORT) is a treatment modality whereby a large single dose of radiation is delivered to a surgically open, exposed cancer site. Typically, a beam of megavoltage electrons is directed at an exposed tumor or tumor bed through a specially designed applicator system. In the last few years, IORT facilities have proliferated around the world. The IORT technique and the applicator systems used at these facilities vary greatly in sophistication and design philosophy. The IORT beam characteristics vary for different designs of applicator systems. It is necessary to document the existing techniques of IORT, to detail the dosimetry data required for accurate delivery of the prescribed dose, and to have a uniform method of dose specification for cooperative clinical trials. The specific charge to the task group includes the following: (a) identify the multidisciplinary IORT team, (b) outline special considerations that must be addressed by an IORT program, (c) review currently available IORT techniques, (d) describe dosimetric measurements necessary for accurate delivery of prescribed dose, (e) describe dosimetric measurements necessary in documenting doses to the surrounding normal tissues, (f) recommend quality assurance procedures for IORT, (g) review methods of treatment documentation and verification, and (h) recommend methods of dose specification and recording for cooperative clinical trials.
引用
收藏
页码:725 / 746
页数:22
相关论文
共 70 条
[1]   INTRA-OPERATIVE IRRADIATION IN ABDOMINAL AND CEREBRAL TUMOURS [J].
ABE, M ;
FUKUDA, M ;
YAMANO, K ;
MATSUDA, S ;
HANDA, H .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1971, 10 (04) :408-&
[2]  
ABE M, 1980, CANCER, V45, P40, DOI 10.1002/1097-0142(19800101)45:1<40::AID-CNCR2820450108>3.0.CO
[3]  
2-2
[4]   TECHNIQUES, INDICATIONS AND RESULTS OF INTRAOPERATIVE RADIOTHERAPY OF ADVANCED CANCERS [J].
ABE, M ;
TAKAHASHI, M ;
YABUMOTO, E ;
ONOYAMA, Y ;
TORIZUKA, K ;
TOBE, T ;
MORI, K .
RADIOLOGY, 1975, 116 (03) :693-702
[5]   INTRA-OPERATIVE RADIOTHERAPY - THE JAPANESE EXPERIENCE [J].
ABE, M ;
TAKAHASHI, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (07) :863-868
[6]  
ABE M, 1974, CANCER, V34, P2034, DOI 10.1002/1097-0142(197412)34:6<2034::AID-CNCR2820340623>3.0.CO
[7]  
2-F
[8]  
ABE M, 1984, INT J RADIAT ONCOL, P1987
[9]   INTRAOPERATIVE RADIOTHERAPY IN LOCALLY ADVANCED RECURRENT COLORECTAL-CANCER [J].
ABUCHAIBE, O ;
CALVO, FA ;
AZINOVIC, I ;
ARISTU, J ;
PARDO, F ;
ALVAREZCIENFUEGOS, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (05) :859-867
[10]   COST-EFFECTIVE, AVAILABLE-ON-DEMAND INTRAOPERATIVE RADIATION-THERAPY [J].
ARCHAMBEAU, JO ;
AITKEN, D ;
POTTS, TM ;
SLATER, JM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (03) :775-778