MR-IMAGING AND CT OF SURGICAL MATERIALS CURRENTLY USED IN OPHTHALMOLOGY - IN-VITRO AND IN-VIVO STUDIES

被引:19
作者
GIRARDOT, C
HAZEBROUCQ, VG
FERYLEMONNIER, E
TUDORET, L
UZAN, E
DELMAR, G
LEGMANN, P
MONDON, H
BONNIN, A
机构
[1] CHU PARIS,HOP COCHIN,DEPT RADIOL A,F-75014 PARIS,FRANCE
[2] CHU PARIS,HOP COCHIN,DEPT OPHTHALMOL,F-75014 PARIS,FRANCE
关键词
COMPUTED TOMOGRAPHY (CT); COMPARATIVE STUDIES; EYE; ABNORMALITIES; MAGNETIC RESONANCE (MR);
D O I
10.1148/radiology.191.2.8153317
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
PURPOSE: To assess methods of imaging postoperative changes in the eyeball by performing in vitro and in vivo studies of the main solid and fluid materials used in the treatment of cataract and retinal detachment. MATERIALS AND METHODS: The samples were analyzed in vitro with computed tomography (CT) and magnetic resonance (MR) imaging performed at 0.5 T. In vivo studies were performed in seven patients who underwent lens implantation (n = 1), scleral buckling with hydrogel or silicone (n = 6), and retinopexy with gas or silicone oil (n = 6). The attenuation and signal intensity of the materials were compared with values for anatomic structures. RESULTS: Lens implants were difficult to visualize. Each scleral buckling and retinopexy material was easily differentiated from the others and from anatomic structures at both CT and MR imaging. CONCLUSION: Postoperative CT or MR imaging may be useful after retinal detachment surgery, particularly when ultrasound is not reliable after intravitreous gas-fluid interchange.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 20 条
[1]
SILICONE ENCIRCLING BANDS FOR RETINAL-DETACHMENT - CT APPEARANCE [J].
BRESSLER, EL ;
WEINBERG, PE ;
ZARET, CR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (05) :960-962
[2]
PERFLUOROCARBON LIQUIDS IN VITREORETINAL SURGERY [J].
CHANG, S .
INTERNATIONAL OPHTHALMOLOGY CLINICS, 1992, 32 (02) :153-163
[3]
ULTRASONIC FINDINGS AFTER TREATMENT OF RETINAL-DETACHMENT BY INTRAVITREAL SILICONE INSTILLATION [J].
CLEMENS, S ;
KROLL, P ;
ROCHELS, R .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1984, 98 (03) :369-373
[4]
FLAMENT J, 1988, B SOC OPHTHALMOL FRA, V10, P1183
[5]
HUMAN EYE - VISUALIZATION OF PERFLUORODECALIN WITH F-19 MR-IMAGING [J].
GEWIESE, BKO ;
NOSKE, W ;
SCHILLING, AM ;
STILLER, DA ;
WOLF, KJ ;
FOERSTER, MH .
RADIOLOGY, 1992, 185 (01) :131-133
[6]
MAGNETIC-RESONANCE-IMAGING IN THE EVALUATION OF VITREORETINAL DISEASE IN EYES WITH INTRAOCULAR SILICONE OIL [J].
GROSS, JG ;
HESSELINK, JR ;
PRESS, GA ;
GOLDBAUM, MH ;
FREEMAN, WR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1990, 110 (04) :366-370
[7]
JAFFE NS, 1990, INTRAOCULAR LENS IMP, P128
[8]
JOHNSON MH, 1984, AM J NEURORADIOL, V5, P59
[9]
LAROCHE L, 1991, ENCY MEDICO CHIRURGI
[10]
MALIGNANT UVEAL MELANOMA AND SIMULATING LESIONS - MR IMAGING EVALUATION [J].
MAFEE, MF ;
PEYMAN, GA ;
GRISOLANO, JE ;
FLETCHER, ME ;
SPIGOS, DG ;
WEHRLI, FW ;
RASOULI, F ;
CAPEK, V .
RADIOLOGY, 1986, 160 (03) :773-780