THE TITANIUM INTRAPROSTATIC STENT - THE UNITED-STATES EXPERIENCE

被引:18
作者
KAPLAN, SA
MERRILL, DC
MOSELY, WG
BENSON, RC
CHIOU, RK
FUSELIER, HA
PARRA, RO
机构
[1] CTR UROL TREATMENT & RES,NASHVILLE,TN
[2] ST LOUIS UNIV,DEPT UROL,ST LOUIS,MO 63103
[3] UNIV CALIF SAN DIEGO,DEPT UROL,LA JOLLA,CA 92093
[4] UNIV NEBRASKA,DEPT UROL,OMAHA,NE 68182
[5] VET ADM MED CTR,DEPT UROL,MARTINEZ,CA 94553
[6] ALTON OCHSNER MED FDN & OCHSNER CLIN,DEPT UROL,NEW ORLEANS,LA 70121
关键词
PROSTATIC HYPERTROPHY; STENTS; TITANIUM; URINARY RETENTION;
D O I
10.1016/S0022-5347(17)35860-3
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
This multicenter, cooperative study represents, the initial United States experience using an expandable, titanium intraprostatic stent in 68 patients (60 to 93 years old). The stents were inserted under direct vision and expanded to 33F using a balloon catheter. All patients had a symptom score analysis, and underwent measurement of peak urine flow and rate and post-void residual urine volume as part of the initial evaluation. Patients were seen at approximately 1, 3, 6 and 18 months after stent insertion (mean followup 16 months). Of the 68 patients 38 presented in urinary retention. The type of anesthesia used included general anesthesia in 6 patients, spinal or epidural anesthesia in 24, intravenous sedation in 20 and intraurethral lidocaine only in 18. All patients were able to void spontaneously within 36 hours after stent insertion. Symptom scores decreased from 16.8 to 3.9, 6.3, 5.0, 5.7 and 3.2 at approximately 1, 3, 6, 12 and 18 months, respectively. Peak urine flow rate increased from 3.9 to 13.8, 11.5, 11.2, 12.4 and 14.4 ml. per second at approximately 1, 3, 6, 12 and 18 months, respectively. Post-void residual urine volume decreased from 74.4 to 30.1, 29.2, 19.8 and 40.2 ml. at approximately 1, 3, 6 and 12 months, respectively. Of the initial 68 patients 5 died of the underlying disorder (all voiding satisfactorily with the stent in place) and 17 underwent uneventful stent removal (10 for technical failure and 7 for treatment failure). Technical failures were secondary to either inaccurate positioning or improper stent sizing. Of the 58 patients with proper placement of the stent and no technical failures 46 (79%) had improvement in symptom scores and urine flow rate. Transient hematuria was noted in 43 patients (63%) and usually resolved within 48 hours. None of the 6 urinary tract infections (9%) was recurrent. In conclusion, the titanium intraprostatic stent, when properly placed, is a promising therapeutic alternative to prostatectomy or long-term catheterization in high risk obstructed patients or those in urinary retention. Studies are currently in progress to determine the long-term efficacy of this therapeutic modality.
引用
收藏
页码:1624 / 1629
页数:6
相关论文
共 32 条
[1]   WALLSTENT ENDOPROSTHESES FOR THE RELIEF OF PROSTATIC URETHRAL OBSTRUCTION IN HIGH-RISK PATIENTS [J].
ADAM, A ;
JAGER, R ;
MCLOUGHLIN, J ;
ELDIN, A ;
MACHAN, L ;
WILLIAMS, G ;
ALLISON, DJ .
CLINICAL RADIOLOGY, 1990, 42 (04) :228-232
[2]  
ASHKEN MH, 1991, EUR UROL, V19, P181
[3]   TRANSURETHRAL MICROWAVE HYPERTHERMIA FOR BENIGN PROSTATIC HYPERPLASIA - PRELIMINARY CLINICAL AND PATHOLOGICAL RESULTS [J].
BAERT, L ;
AMEYE, F ;
WILLEMEN, P ;
VANDENHOVE, J ;
LAUWERYNS, J ;
ASTRAHAN, M ;
PETROVICH, Z .
JOURNAL OF UROLOGY, 1990, 144 (06) :1383-1387
[4]  
BLANDY JP, 1978, UROL INT, V33, P159, DOI 10.1159/000280193
[5]  
BLUTE ML, 1991, J ANDROL, V12, P429
[6]   PERMANENTLY IMPLANTED URETHRAL STENT FOR PROSTATIC OBSTRUCTION IN THE UNFIT PATIENT - PRELIMINARY-REPORT [J].
CHAPPLE, CR ;
MILROY, EJG ;
RICKARDS, D .
BRITISH JOURNAL OF UROLOGY, 1990, 66 (01) :58-65
[7]  
COSTELLO A J, 1992, Journal of Urology, V147, p306A
[8]  
FABIAN KM, 1980, UROLOGE A, V19, P236
[9]  
GILLAT G, 1992, J UROL 2, V147, pA308
[10]   PROSTATIC STENTING FOR OUTFLOW OBSTRUCTION [J].
HARRISON, NW ;
DESOUZA, JV .
BRITISH JOURNAL OF UROLOGY, 1990, 65 (02) :192-196