PRACTICAL T2 QUANTITATION FOR CLINICAL-APPLICATIONS

被引:327
作者
POON, CS
HENKELMAN, RM
机构
[1] Sunnybrook Health Science Centre, Toronto, Ontario, M4N 3M5, Reichmann Research Building
[2] Department of Medical Biophysics, University of Toronto
关键词
PULSE SEQUENCES; RELAXOMETRY; TISSUE CHARACTERIZATION;
D O I
10.1002/jmri.1880020512
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Many studies have investigated the use of magnetic resonance relaxation times for tissue characterization. A number have been performed in vivo with clinical whole-body imagers. Unfortunately, the results have yet to establish the role of quantitative tissue relaxation time measurements in clinical diagnosis. One of the major problems is that the techniques used in many of these studies are error prone, making the results inconclusive. In the present study, the problems associated with clinical T2 measurements were systematically evaluated in an attempt to obtain reliable in vivo quantitation. The authors demonstrate that spoiler gradients are the most effective technique for artifact suppression but that they render ineffective radio-frequency phase schemes such as the Meiboom-Gill modification to the Carr-Purcell sequence to compensate experimental imperfections. The present study results in a more reliable multi-echo sequence for T2 measurement. Preliminary clinical results in brain and cervix demonstrate the performance of the new technique.
引用
收藏
页码:541 / 553
页数:13
相关论文
共 55 条
[1]  
Damadian R, Tumor detection by nuclear magnetic resonance, Science, 171, pp. 1151-1153, (1971)
[2]  
Bottomley PA, Hardy CJ, Argersinger RE, Allen-Moore G, A review of <sup>1</sup>H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic?, Med Phys, 14, pp. 1-37, (1987)
[3]  
(1989)
[4]  
Moore SG, Gooding CA, Brasch RC, Et al., Bone marrow in children with acute lymphocytic leukemia: MR relaxation times, Radiology, 160, pp. 237-240, (1986)
[5]  
Santoni R, Bucciolini M, Cionini L, Ciraolo L, Renzi R, Modifications of relaxation times induced by radiation therapy in cervical carcinoma: preliminary results, Clin Radiol, 38, pp. 569-573, (1987)
[6]  
Just M, Thelen M, Tissue characterization with T1, T2, and proton density values: results in 160 patients with brain tumors, Radiology, 169, pp. 779-785, (1988)
[7]  
Shioya S, Christman R, Ailion DC, An in vivo NMR imaging determination of multiexponential Hahn T2 of normal lung, Magn Reson Med, 16, pp. 49-56, (1990)
[8]  
McSweeney MB, Small WC, Cerny V, Sewell W, Powell RW, Goldstein JH, Magnetic resonance imaging in the diagnosis of breast disease: use of transverse relaxation times, Radiology, 153, pp. 741-744, (1984)
[9]  
Stark DD, Moseley ME, Bacon BR, Et al., Magnetic resonance imaging and spectroscopy of hepatic iron overload, Radiology, 154, pp. 137-142, (1985)
[10]  
Liu P, Sullivan H, Henkelman RM, Benson L, Kucharzyk W, Olivari N, Comparison of gradient echo and spin echo techniques in detecting myocardial iron in patients with hemochromatosis (abstr), Book of abstracts: Society of Magnetic Resonance in Medicine 1988, (1988)