SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY WITH TL-201 DURING ADENOSINE-INDUCED CORONARY HYPEREMIA - CORRELATION WITH CORONARY ARTERIOGRAPHY, EXERCISE THALLIUM IMAGING AND 2-DIMENSIONAL ECHOCARDIOGRAPHY

被引:208
作者
NGUYEN, T [1 ]
HEO, J [1 ]
OGILBY, JD [1 ]
ISKANDRIAN, AS [1 ]
机构
[1] PRESBYTERIAN MED CTR,PHILADELPHIA HEART INST,39TH ST,MARKET ST,PHILADELPHIA,PA 19104
关键词
D O I
10.1016/0735-1097(90)90379-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The feasibility, safety and diagnostic accuracy of single photon emission computed tomography (SPECT) with thallium-201 imaging during adenosine-induced coronary hyperemia were evaluated in 53 patients with and 7 without coronary artery disease proved by coronary angiography. Adenosine was infused intravenously at a dose of 0.14 mg/kg body weight per min for 6 min and thallium was injected at 3 min. Adenosine caused an increase in heart rate (68 ± 12 at baseline versus 87 ± 18 beats/mm at peak effect, p < 0.0001) but no change in blood pressure. The sensitivity and specificity were 92% (95% confidence intervals 81% to 98%) and 100% (95% confidence intervals 59% to 100%), respectively; 20 (61%) of 33 patients with multivessel coronary artery disease were also correctly identified. In 30 patients, the predictive accuracy of adenosine thallium imaging was slightly higher than that exercise SPECT thallium imaging (90% versus 80%, p = NS) (95% confidence intervals 72% to 97% and 61% to 92%, respectively). In 25 patients, two-dimensional echocardiography during adenosine infusion disclosed a new wall motion abnormality in 2 (10%) of 20 patients with coronary artery disease; 80% of these patients had reversible thallium defects (p < 0.001). Side effects were mild and transient; aminophylline was used in only three patients. Thus, adenosine SPECT thallium imaging provides a high degree of accuracy in the diagnosis of coronary artery disease. The results are comparable with those of exercise SPECT thallium imaging. Most reversible defects in the adenosine study are not associated with any transient wall motion abnormality. © 1990.
引用
收藏
页码:1375 / 1383
页数:9
相关论文
共 25 条
[1]   THE CARDIAC EFFECTS OF ADENOSINE [J].
BELARDINELLI, L ;
LINDEN, J ;
BERNE, RM .
PROGRESS IN CARDIOVASCULAR DISEASES, 1989, 32 (01) :73-97
[2]   CARDIOVASCULAR AND RESPIRATORY EFFECTS OF ADENOSINE IN CONSCIOUS MAN - EVIDENCE FOR CHEMORECEPTOR ACTIVATION [J].
BIAGGIONI, I ;
OLAFSSON, B ;
ROBERTSON, RM ;
HOLLISTER, AS ;
ROBERTSON, D .
CIRCULATION RESEARCH, 1987, 61 (06) :779-786
[3]   HIGH-DOSE DIPYRIDAMOLE ECHOCARDIOGRAPHY EARLY AFTER UNCOMPLICATED ACUTE MYOCARDIAL-INFARCTION - CORRELATION WITH EXERCISE TESTING AND CORONARY ANGIOGRAPHY [J].
BOLOGNESE, L ;
SARASSO, G ;
ARALDA, D ;
BONGO, AS ;
ROSSI, L ;
ROSSI, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (02) :357-363
[4]   EFFECT OF INFUSED ADENOSINE ON CARDIAC-OUTPUT AND SYSTEMIC RESISTANCE IN NORMAL SUBJECTS [J].
BUSH, A ;
BUSST, CM ;
CLARKE, B ;
BARNES, PJ .
BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1989, 27 (02) :165-171
[5]  
CARUSO AC, 1989, CIRCULATION S2, V80, P2508
[6]   HEMODYNAMIC, ANGIOGRAPHIC AND SCINTIGRAPHIC CORRELATES OF POSITIVE EXERCISE ELECTROCARDIOGRAMS - EMPHASIS ON STRONGLY POSITIVE EXERCISE ELECTROCARDIOGRAMS [J].
COLBY, J ;
HAKKI, A ;
ISKANDRIAN, AS ;
MATTLEMAN, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (01) :21-29
[7]   ASSESSING STENOSIS SEVERITY - CORONARY FLOW RESERVE, COLLATERAL FUNCTION, QUANTITATIVE CORONARY ARTERIOGRAPHY, POSITRON IMAGING, AND DIGITAL SUBTRACTION ANGIOGRAPHY - A REVIEW AND ANALYSIS [J].
DEMER, L ;
GOULD, KL ;
KIRKEEIDE, R .
PROGRESS IN CARDIOVASCULAR DISEASES, 1988, 30 (05) :307-322
[8]  
FITZGERALD GA, 1987, NEW ENGL J MED, V316, P1247
[9]  
FULLER RW, 1987, BRIT J CLIN PHARMACO, V24, P309
[10]   CORONARY STEAL - IS IT CLINICALLY IMPORTANT [J].
GOULD, KL .
CHEST, 1989, 96 (02) :227-229