Magnetic resonance imaging analysis of the bioabsorbable Milagro (TM) interference screw for graft fixation in anterior cruciate ligament reconstruction

被引:46
作者
Frosch, K. -H. [1 ]
Sawallich, T. [1 ]
Schuetze, G. [2 ]
Losch, A. [3 ]
Walde, T. [1 ]
Balcarek, P. [1 ]
Konietschke, F. [4 ]
Stuermer, K. M. [1 ]
机构
[1] Univ Gottingen, Dept Trauma Surg, Plast & Reconstruct Surg, Robert Koch Str 40, D-37075 Gottingen, Germany
[2] Univ Gottingen, Dept Neuroradiol, D-37075 Gottingen, Germany
[3] Klin Dr Lehmann, D-24534 Neumunster, Germany
[4] Univ Gottingen, Dept Med Stat, D-37073 Gottingen, Germany
来源
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION | 2009年 / 4卷 / 02期
关键词
Anterior cruciate ligament; Graft fixation; Interference screw; Milagro (TM) screw; Magnetic resonance imaging;
D O I
10.1007/s11751-009-0063-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Ligament graft fixation with bioabsorbable interference screws is a standard procedure in cruciate ligament replacement. Previous screw designs may resorb incompletely, and can cause osteolysis and sterile cysts despite being implanted for several years. The aim of this study was to examine the in vivo degradation and biocompatibility of the new Milagro (TM) interference screw (Mitek, Norderstedt, Germany). The Milagro (TM) interference screw is made of 30% beta-TCP (TriCalcium phosphate) and 70% PLGA (Poly-lactic-co-glycolic acid). In the period between June 2005 and February 2006, 38 patients underwent graft fixation with Milagro (TM) screws in our hospital. Arthroscopic ACL reconstruction was performed using hamstring tendon grafts in all the patients. MR imaging was performed on 12 randomly selected patients out of the total of 38 at 3, 6 and 12 months after surgery. During the examination, the volume loss of the screw, tunnel enlargement, presence of osteolysis, fluid lines, edema and postoperative screw replacement by bone tissue were evaluated. There was no edema or signs of inflammation around the bone tunnels. At 3, 6 and 12 months, the tibial screws showed an average volume loss of 0, 8.1% (+/- 7.9%) and 82.6% (+/- 17.2%, P < 0.05), respectively. The femoral screws showed volume losses of 2.5% (+/- 2.1%), 31.3% (+/- 21.6%) and 92.02% (+/- 6.3%, P < 0.05), respectively. The femoral tunnel enlargement was 47.4% (+/- 43.8%) of the original bone tunnel volume after 12 months, and the mean tunnel volume of the tibial tunnel was -9.5% (+/- 58.1%) compared to the original tunnel. Bone ingrowth was observed in all the patients. In conclusion, the resorption behaviour of the Milagro (TM) screw is closely linked to the graft healing process. The screws were rapidly resorbed after 6 months and, at 12 months, only the screw remnants were detectable. Moreover, the Milagro (TM) screw is biocompatible and osteoconductive, promoting bone ingrowth during resorption. Tunnel enlargement is not prevented in the first months but is reduced by bone ingrowth after 12 months.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 28 条
[1]
Anterior cruciate ligament reconstruction with bioabsorbable polyglycolic acid interference screws:: MR imaging follow-up [J].
Bach, FD ;
Carlier, RY ;
Elis, JB ;
Mompoint, DM ;
Feydy, A ;
Judet, O ;
Beaufils, P ;
Vallée, C .
RADIOLOGY, 2002, 225 (02) :541-550
[2]
Long-term absorption of β-tricalcium phosphate poly-L-lactic acid interference screws [J].
Barber, F. Alan ;
Dockery, William D. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (04) :441-447
[3]
Long-term absorption of poly-L-lactic acid interference screws [J].
Barber, F. Alan ;
Dockery, W. Dee .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (08) :820-826
[4]
Bone regeneration of porous β-tricalcium phosphate (Conduit™ TCP) and of biphasic calcium phosphate ceramic (Biosel®) in trabecular defects in sheep [J].
Bodde, Esther W. H. ;
Wolke, Joop G. C. ;
Kowalski, Rick S. Z. ;
Jansen, John A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 82A (03) :711-722
[5]
FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596
[6]
A prospective evaluation of tunnel enlargement in anterior cruciate ligament reconstruction with hamstrings: extracortical versus anatomical fixation [J].
Buelow, JU ;
Siebold, R ;
Ellermann, A .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (02) :80-85
[7]
Cain EL, 2005, ORTHOPEDICS, V28, P779
[8]
Tunnel widening in anterior cruciate ligament reconstruction: a prospective evaluation of hamstring and patella tendon grafts [J].
Clatworthy, MG ;
Annear, P ;
Bulow, JU ;
Bartlett, RJ .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (03) :138-145
[9]
Magnetic resonance imaging analysis of bioabsorbable interference screws used for fixation of bone-patellar tendon-bone autografts in endoscopic reconstruction of the anterior cruciate ligament [J].
Drogset, JO ;
Grontvedt, T ;
Myhr, G .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (07) :1164-1169
[10]
Bioabsorbable polyglyconate interference screw fixation in anterior cruciate ligament reconstruction: A prospective computed tomography-controlled study [J].
Fink, C ;
Benedetto, KP ;
Hackl, W ;
Hoser, C ;
Freund, MC ;
Rieger, M .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2000, 16 (05) :491-498