EMI SHIELDING MEASUREMENTS OF CONDUCTIVE POLYMER BLENDS

被引:385
作者
COLANERI, NF
SHACKLETTE, LW
机构
[1] Allied-Signal, Inc., Research and Technology, Morristown
关键词
D O I
10.1109/19.137363
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Shielding efficiencies for a number of blends containing a variety of conductive fillers including intrinsically conductive polymers have been measured in the near-field with a dual-chamber box and in the far-field with a transmission line fixture. Although all samples tested satisfied the classical good-conductor approximation, most of them exhibited a crossover from being electrically thin (thickness < skin depth) to being electrically thick (thickness > skin depth) over the frequency range of interest, 1 MHz to 3 GHz. The theoretical relations for both near-field and far-field shielding which are prevalent in the literature do not accurately describe this region of cross-over. We have derived expressions which describe the behavior accurately over the entire range of interest. Far-field shielding efficiencies as high as 70 dB at 1 GHz were measured for purely organic composites consisting of an intrinsically conductive polymer, polyaniline, dispersed in a thermoplastic matrix.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 20 条