Multicenter evaluation of a new capillary blood prothrombin time monitoring system

被引:65
作者
vandenBesselaar, AMHP
Breddin, K
Lutze, G
ParkerWilliams, J
Taborski, U
Vogel, G
Tritschler, W
Zerback, R
Leinberger, R
机构
[1] BOEHRINGER MANNHEIM GMBH,DEPT EVALUAT,W-6800 MANNHEIM,GERMANY
[2] UNIV LEIDEN HOSP,DEPT HEMATOL,CTR HEMOSTASIS & THROMBOSIS RES,2300 RC LEIDEN,NETHERLANDS
[3] UNIV FRANKFURT KLINIKUM,ZENTRUM INNERE MED,ABT ANGIOL,FRANKFURT,GERMANY
[4] UNIV MAGDEBURG,INST KLIN CHEM,MAGDEBURG,GERMANY
[5] ST GEORGE HOSP,SCH MED,LONDON,ENGLAND
[6] KERCKHOFF KLIN,ABT HAMOSTASEOL & TRANSFUS MED,BAD NAUHEIM,GERMANY
[7] MED HSCH ERFURT,ERFURT,GERMANY
关键词
prothrombin time; decentralized testing; multicenter evaluation; capillary blood; oral anticoagulants; laboratory control;
D O I
10.1097/00001721-199512000-00005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The analytical performance of the new capillary blood prothrombin time monitoring system CoaguChek(TM) was examined in a multicenter evaluation at six hospitals. The coefficients of variation of the INR obtained in the CoaguChek(TM) imprecision study were approximately 7% in the control plasma provided (within-run and day-to-day) and 4% in blood (within-run). The prothrombin times were ascertained in capillary blood (CoaguChek(TM) PT Test) and citrated venous plasma (Hepato Quick, Thromborel(TM) S) from 359 patients under oral anticoagulation therapy with phenprocoumon, acenocoumarin or warfarin. The agreement with the test results obtained with the comparison methods was acceptable versus Hepato Quick assay (n = 359; y = 1.23 x - 0.49, r = 0.888) and good versus Thromborel(TM)S method (n = 359; y = 1.09 x - 0.28, r = 0.895). A simplified assessment of all test results (n = 795) in a nine-field comparison table showed a concordance with the comparison methods of more than 80 (Hepato Quick: 81%, Thromborel(TM) S: 83%), The concordance between Hepato-Quick and Thromborel(TM) S was slightly higher (88%). Its good analytical performance and convenient handling recommend the CoaguChek(TM) system as a suitable system for decentralized prothrombin time testing.
引用
收藏
页码:726 / 732
页数:7
相关论文
共 15 条
[1]   EVALUATION OF A PORTABLE PROTHROMBIN TIME MONITOR FOR HOME-USE BY PATIENTS WHO REQUIRE LONG-TERM ORAL ANTICOAGULANT-THERAPY [J].
ANDERSON, DR ;
HARRISON, L ;
HIRSH, J .
ARCHIVES OF INTERNAL MEDICINE, 1993, 153 (12) :1441-1447
[2]   PATIENT SELF-MANAGEMENT OF ORAL ANTICOAGULATION GUIDED BY CAPILLARY (FINGERSTICK) WHOLE-BLOOD PROTHROMBIN TIMES [J].
ANSELL, J ;
HOLDEN, A ;
KNAPIC, N .
ARCHIVES OF INTERNAL MEDICINE, 1989, 149 (11) :2509-2511
[3]  
BECKER DM, 1993, ARCH PATHOL LAB MED, V117, P602
[4]  
BEESER H, 1991, LAB MED, V15, P158
[5]  
BERNARDO A, 1995, HERZ KREISLAUF, V27, P71
[6]  
BERNARDO A, 1992, THROMBOSIS EMBOLISM, P325
[7]   A NOVEL WHOLE-BLOOD CAPILLARY TECHNIQUE FOR MEASURING THE PROTHROMBIN TIME [J].
LUCAS, FV ;
DUNCAN, A ;
JAY, R ;
COLEMAN, R ;
CRAFT, P ;
CHAN, B ;
WINFREY, L ;
MUNGALL, DR ;
HIRSH, J .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 88 (04) :442-446
[8]  
OBERHARDT BJ, 1991, CLIN CHEM, V37, P520
[9]  
PASSING H, 1983, J CLIN CHEM CLIN BIO, V21, P709
[10]  
QUICK AJ, 1935, J BIOL CHEM, V109, P72