ACCURATE ATTENUATION CORRECTION FOR A 3D PET SYSTEM

被引:9
作者
MCKEE, BTA [1 ]
CLACK, R [1 ]
HARVEY, PJ [1 ]
HILTZ, LG [1 ]
HOGAN, MJ [1 ]
HOWSE, DC [1 ]
机构
[1] QUEENS UNIV,DEPT PHYS,KINGSTON K7L 3N6,ONTARIO,CANADA
关键词
D O I
10.1088/0031-9155/36/5/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate attenuation correction has been developed for a small-volume three-dimensional positron emission tomography (PET) system. Transmission data were measured as twenty-four 2D slices which were reconstructed and combined to form a 3D attenuation image. Emission data were reconstructed using a backproject-then-filter technique, and each event was corrected for attenuation at backprojection time by a reprojection through the attenuation image. This correction restores the spatial invariance of the point response function, thus allowing a valid deconvolution and producing an undistorted emission image. Scattering corrections were not applied to either the transmission or the emission data but simulation studies indicated that scattering made only a small contribution to the attenuation measurement. Results are presented for two phantoms, in which transmission scans of 57 500 and 18 700 events/slice were used to correct emission images of 5.2 and 2.8 million events. Although the attenuation images had poor statistical accuracy and a resolution of 13 mm, the method resulted in accurate attenuation-corrected images with no degradation in image resolution (which was 3 mm for the first emission image), and with little effect on image noise.
引用
收藏
页码:603 / 619
页数:17
相关论文
共 24 条
[1]  
BATES RHT, 1971, NEW ZEAL J SCI, V14, P883
[2]   CYLINDRICAL PET DETECTOR DESIGN [J].
BURNHAM, CA ;
KAUFMAN, DE ;
CHESLER, DA ;
STEARNS, CW ;
WOLFSON, DR ;
BROWNELL, GL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :675-679
[3]   INCREASED SENSITIVITY AND FIELD OF VIEW FOR A ROTATING POSITRON CAMERA [J].
CLACK, R ;
TOWNSEND, D ;
JEAVONS, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (11) :1421-1431
[4]   A STUDY OF THE POSSIBILITY OF USING MULTI-SLICE PET SYSTEMS FOR 3D IMAGING [J].
DAHLBOM, M ;
ERIKSSON, L ;
ROSENQVIST, G ;
BOHM, C .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :1066-1071
[5]   PROBLEMS IN SIGNAL-TO-NOISE RATIO FOR ATTENUATION CORRECTION IN HIGH-RESOLUTION PET [J].
DAHLBOM, M ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :288-293
[6]   3-DIMENSIONAL IMAGE-RECONSTRUCTION FROM COMPLETE PROJECTIONS [J].
DEFRISE, M ;
TOWNSEND, DW ;
CLACK, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (05) :573-587
[7]   IMAGE-RECONSTRUCTION FOR A 3D PET SYSTEM USING A MINIMUM NORM CONSTRAINT [J].
HOGAN, MJ ;
HARVEY, PJ ;
HOWSE, DC ;
MCKEE, BTA .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (01) :35-46
[8]  
HOGAN MJ, 1986, THESIS QUEENS U KING
[9]   A PRELIMINARY EVALUATION OF A POSITRON CAMERA SYSTEM USING WEIGHTED DECODING OF INDIVIDUAL CRYSTALS [J].
HOLTE, S ;
ERIKSSON, L ;
LARSSON, JE ;
ERICSON, T ;
STJERNBERG, H ;
HANSEN, P ;
BOHM, C ;
KESSELBERG, M ;
ROTA, E ;
HERZOG, H ;
FEINENDEGEN, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :730-734
[10]  
HUANG SC, 1979, J COMPUT ASSIST TOMO, V3, P804