DETERMINATION OF CARDIAC-OUTPUT DURING POSITIVE ENDEXPIRATORY PRESSURE - NONINVASIVE ELECTRICAL BIOIMPEDANCE COMPARED WITH STANDARD THERMODILUTION

被引:35
作者
CASTOR, G
MOLTER, G
HELMS, J
NIEDERMARK, I
ALTMAYER, P
机构
[1] Institute of Anesthesiology, University Hospital
关键词
D O I
10.1097/00003246-199005000-00017
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Many investigators have demonstrated the accuracy and reliability of thoracic electrical bioimpedance (TEB) in spontaneously breathing patients and under mechanical intermittent positive-pressure ventilation. Most of these studies showed a good correlation between TEB and invasive methods, such as thermodilution (TD) or the Fick method. But during PEEP, contrary results occur when comparing TEB and TD. In six patients undergoing neurosurgical interventions, TEB cardiac output measurements were compared during zero end-expiratory pressure (ZEEP) and during PEEP at 8 cm H2O with a low respiratory rate. The data revealed a good correlation during ZEEP (r = .93) and during PEEP (r = .91). There was no significant statistical difference when measuring cardiac output by TEB during ventilation with PEEP. During normal or decreased cardiac output, TEB overestimated cardiac output compared with TD whereas TEB underestimated cardiac output compared with TD during increased cardiac output, especially during PEEP.
引用
收藏
页码:544 / 546
页数:3
相关论文
共 19 条
[1]   A NEW STROKE VOLUME EQUATION FOR THORACIC ELECTRICAL BIOIMPEDANCE - THEORY AND RATIONALE [J].
BERNSTEIN, DP .
CRITICAL CARE MEDICINE, 1986, 14 (10) :904-909
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BOLDT J, 1988, ANAESTHESIST, V37, P218
[4]  
CASTOR G, 1988, ANASTH INTENSIVMED, V29, P339
[5]   CARDIAC-OUTPUT MEASURED BY TRANS-THORACIC IMPEDANCE CARDIOGRAPHY AT REST, DURING EXERCISE AND AT VARIOUS LUNG-VOLUMES [J].
EDMUNDS, AT ;
GODFREY, S ;
TOOLEY, M .
CLINICAL SCIENCE, 1982, 63 (02) :107-113
[6]   CLINICAL-EVALUATION OF IMPEDANCE CARDIOGRAPHY [J].
GOLDSTEIN, DS ;
CANNON, RO ;
ZIMLICHMAN, R ;
KEISER, HR .
CLINICAL PHYSIOLOGY, 1986, 6 (03) :235-251
[7]  
JANSEN JRC, 1986, INTENS CARE MED, V12, P71
[8]  
JANSEN JRC, 1981, J APPL PHYSIOL, V50, P584
[9]   DETERMINATION OF CARDIAC-OUTPUT USING ENSEMBLE-AVERAGED IMPEDANCE CARDIOGRAMS [J].
MUZI, M ;
EBERT, TJ ;
TRISTANI, FE ;
JEUTTER, DC ;
BARNEY, JA ;
SMITH, JJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (01) :200-205
[10]   EFFECTS OF INTERMITTENT POSITIVE-PRESSURE VENTILATION ON CARDIAC-OUTPUT MEASUREMENTS BY THERMODILUTION [J].
OKAMOTO, K ;
KOMATSU, T ;
KUMAR, V ;
SANCHALA, V ;
KUBAL, K ;
BHALODIA, R ;
SHIBUTANI, K .
CRITICAL CARE MEDICINE, 1986, 14 (11) :977-980