ASSESSMENT OF INTERLABORATORY PERFORMANCE ON THE MEASUREMENT OF BLOOD LEAD LEVELS IN TAIWANESE ADULTS

被引:21
作者
LIOU, SH
YANG, GY
WU, TN
KO, YC
LEE, CC
HO, ST
LAI, JS
WU, YQ
CHIANG, HC
KO, KN
CHANG, PY
机构
[1] TAIPEI VET GEN HOSP, DEPT MED, DIV CLIN TOXICOL, TAIPEI, TAIWAN
[2] EXECUT YUAN, DEPT HLTH, TAICHUNG, TAIWAN
[3] KAOHSIUNG MED COLL, SCH PUBL HLTH, KAOHSIUNG, TAIWAN
[4] NATL CHENG KUNG UNIV, COLL MED, DEPT ENVIRONM & OCCUPAT HLTH, TAINAN 70101, TAIWAN
[5] CHIA NAN JR COLL PHARM, DEPT IND SAFETY & HYG, TAINAN, TAIWAN
[6] CHINA MED COLL, INST ENVIRONM HLTH, TAICHUNG, TAIWAN
[7] TAIWAN PROV HSINCHU HOSP, DEPT FAMILY & OCCUPAT MED, HSINCHU, TAIWAN
关键词
BLOOD LEAD LEVEL; ACCURACY TEST; PRECISION TEST; INTERLABORATORY VARIATIONS; INTERTIME VARIATIONS;
D O I
10.2486/indhealth.33.181
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this proficiency study was to assess the accuracy and consistency of blood lead level (BLLs) measurements in a study of Taiwanese adults. Three methods, including a certified blood accuracy test, an interlaboratory precision test and an intertime repeated measurement test, were applied to the six participating laboratories. Accuracy tests showed that most of the blood lead measurements were within the acceptable criteria proposed by United States Center for Disease Control and Prevention (U.S. CDC). However, an average of 11% underestimation was found at BLLs below 15 mu g/dl. Coefficients of variation (CVs) were high in the first 3 months. After technical improvements, the CVs were reduced to acceptable limits of around 15% at low target lead values and 7% at high lead values. Interlaboratory variations of measurements in blood from ten normal healthy donors showed that the standard deviations were less than 2 mu g/dl, which is within the acceptable criteria of +/-4 mu g/dl, in 8 out of 10 samples. Repeated measurements of BLLs in 54 blood samples over two months showed that most of the differences were within the acceptable range with a few exceptions. The mean BLLs measured in the baseline (pre-test) and two months later (post-test) were nearly identical. This proficiency test provides comparable and reliable results of BLL estimations in this multilaboratory study. However, the accuracy and consistency at low BLLs need to be improved.
引用
收藏
页码:181 / 190
页数:10
相关论文
共 22 条
[1]  
BOONE J, 1979, CLIN CHEM, V25, P389
[2]   BLOOD LEAD LEVELS IN THE US POPULATION - PHASE-1 OF THE 3RD NATIONAL-HEALTH AND NUTRITION EXAMINATION SURVEY (NHANES-III, 1988 TO 1991) [J].
BRODY, DJ ;
PIRKLE, JL ;
KRAMER, RA ;
FLEGAL, KM ;
MATTE, TD ;
GUNTER, EW ;
PASCHAL, DC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (04) :277-283
[3]  
BULLOCK DG, 1989, CLIN CHEM, V32, P1884
[4]  
CLAEYS F, 1992, CADMIUM HUMAN ENV TO, P83
[5]   LABORATORIES WHICH CONDUCT LEAD ANALYSES ON BIOLOGIC SPECIMENS [J].
DONOVAN, DT ;
VOUGHT, VM ;
RAKOW, AB .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1971, 23 (02) :111-&
[6]   LOWERING TIME TREND OF BLOOD LEAD LEVELS IN BELGIUM SINCE 1978 [J].
DUCOFFRE, G ;
CLAEYS, F ;
BRUAUX, P .
ENVIRONMENTAL RESEARCH, 1990, 51 (01) :25-34
[7]   DECREASED BLOOD LEAD LEVELS IN RESIDENTS OF STOCKHOLM FOR THE PERIOD 1980-1984 [J].
ELINDER, CG ;
FRIBERG, L ;
LIND, B ;
NILSSON, B ;
SVARTENGREN, M ;
OVERMARK, I .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1986, 12 (02) :114-120
[8]   TRENDS IN BLOOD LEAD LEVELS IN CHRISTCHURCH (NZ) AND ENVIRONS 1978-85 [J].
HINTON, D ;
COOPE, PA ;
MALPRESS, WA ;
JANUS, ED .
JOURNAL OF EPIDEMIOLOGY AND COMMUNITY HEALTH, 1986, 40 (03) :244-248
[9]   INTERLABORATORY EVALUATION OF RELIABILITY OF BLOOD LEAD ANALYSES [J].
KEPPLER, JF ;
MAXFIELD, ME ;
MOSS, WD ;
TIETJEN, G ;
LINCH, AL .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1970, 31 (04) :412-&
[10]   BLOOD LEAD LEVELS IN THE GENERAL-POPULATION OF TAIWAN, REPUBLIC-OF-CHINA [J].
LIOU, SH ;
WU, TN ;
CHIANG, HC ;
YANG, GY ;
WU, YQ ;
LAI, JS ;
HO, ST ;
GUO, YL ;
KO, YC ;
CHANG, PY .
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 1994, 66 (04) :255-260