PREPARATIVE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON A UNIQUE HIGH-SPEED MACROPOROUS RESIN

被引:62
作者
LLOYD, LL
WARNER, FP
机构
[1] Polymer Laboratories Ltd., Church Stretton, Shropshire SY6 6AX, Essex Road
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 512卷
关键词
D O I
10.1016/S0021-9673(01)89502-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of high-performance liquid chromatography (HPLC) for the analysis and purification of biological macromolecules has increased with the commercial availability of packing materials spefically designed for large-molecule analysis. However, the speed of analysis is limited as the efficiency of the HPLC columns for macromolecules has been significantly lower that that acheived for small molecule separations. One possible solution to the speed/capacity/resolution triangle experienced with large biological molecules is to increase the pore size of the HPLC matrix. A rigid macroporous polymer with a 4000 Å pore size has, therefore, been developed for evaluation as a high performance matrix for macromolecule HPLC separations. The mechanical stability of this polymer enables the material to be packed in conventional columns, 4.6 mm I.D., and operated under HPLC conditions of flow rate and pressure. The high speed, fast flow matrices evaluated are for reversed-phase HPLC, PLRP-S 4000 Å, and for anion-exchange HPLC, PL-SAX 4000 Å. The matrices/columns have been assessed for stability, permeability, efficiency, selectivity and capacity with macromolecules and their suitability for analytical and preparative applications evaluated. © 1990.
引用
收藏
页码:365 / 376
页数:12
相关论文
共 23 条
  • [1] ANSPACH B, 1984, 4TH INT S HPLC PROT
  • [2] BRISTOW PA, 1976, LIQUID CHROMATOGRAPH, P41
  • [3] RAPID CATION-EXCHANGE CHROMATOGRAPHY OF HEMOGLOBINS AND OTHER PROTEINS
    BURKE, DJ
    DUNCAN, JK
    SIEBERT, C
    OTT, GS
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 359 : 533 - 540
  • [4] CHANG SH, 1976, J CHROMATOGR, V112, P103
  • [5] CHAPLIN MF, 1986, CARBOHYDRATE ANAL PR, P3
  • [6] DAWKINS JV, 1975, MAKROMOL CHEM, V176, P1795
  • [7] THEORETICAL INVESTIGATION OF THE OPTIMUM PARTICLE-SIZE FOR THE RESOLUTION OF PROTEINS BY SIZE-EXCLUSION CHROMATOGRAPHY
    GUIOCHON, G
    MARTIN, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 326 (JUN): : 3 - 32
  • [8] MEASUREMENT OF ADSORPTION-ISOTHERMS BY LIQUID-CHROMATOGRAPHY
    JACOBSON, J
    FRENZ, J
    HORVATH, C
    [J]. JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC): : 53 - 68
  • [9] EVALUATION OF ADVANCED SILICA PACKINGS FOR THE SEPARATION OF BIO-POLYMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .5. PERFORMANCE OF NONPOROUS MONODISPERSE 1.5-MU-M BONDED SILICAS IN THE SEPARATION OF PROTEINS BY HYDROPHOBIC-INTERACTION CHROMATOGRAPHY
    JANZEN, R
    UNGER, KK
    GIESCHE, H
    KINKEL, JN
    HEARN, MTW
    [J]. JOURNAL OF CHROMATOGRAPHY, 1987, 397 : 91 - 97
  • [10] EVALUATION OF ADVANCED SILICA PACKINGS FOR THE SEPARATION OF BIO-POLYMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .6. DESIGN, CHROMATOGRAPHIC PERFORMANCE AND APPLICATION OF NON-POROUS SILICA-BASED ANION-EXCHANGERS
    JILGE, G
    UNGER, KK
    ESSER, U
    SCHAFER, HJ
    RATHGEBER, G
    MULLER, W
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 476 : 37 - 48