EXPERIMENTAL-STUDY OF HEAT-TRANSFER CHARACTERISTICS DUE TO CONFINED IMPINGING 2-DIMENSIONAL JETS

被引:17
作者
ICHIMIYA, K [1 ]
HOSAKA, N [1 ]
机构
[1] HONDA TECH RES INST LTD,TOCHIGI,JAPAN
关键词
FORCED CONVECTION; IMPINGEMENT HEAT TRANSFER; NOZZLE ARRAY; JET FLOW;
D O I
10.1016/0894-1777(92)90124-N
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental results are presented for characteristics of impingement heat transfer caused by three slot jets. Experimental values were obtained for the dimensionless distance H = 0.5-3, dimensionless pitch P = 6-16, and Reynolds number Re = 500-8000. For laminar impinging flow, they were compared with numerical results. For turbulent impinging flow, two peaks of the local Nusselt number were obtained behind the second nozzle. The position of the second peak approached the nozzle as the space between nozzle and impinged surface decreased. The average Nusselt number between the central and second nozzles was determined from the ratio P/H and the Reynolds number based on the pitch of the nozzles.
引用
收藏
页码:803 / 807
页数:5
相关论文
共 8 条
[1]  
FLORSCHUETZ LW, 1987, ASME, V109, P74
[2]  
GARDON R, 1966, ASME, V88, P101
[3]  
HAN LS, 1983, TOKYO INT GAS TURBIN, P75
[4]  
ICHIMIYA K, 1986, JT JSME B, V52, P904
[5]  
ICHIMIYA K, 1990, T JSME B, V56, P1727
[6]  
Kline S.J., 1953, J I ENG, V1, P3, DOI DOI 10.1016/J.CHAOS.2005.11.046
[7]  
MARTIN H, 1977, ADV HEAT TRANSFER, V13, P1
[8]  
1986, ANSIASMEPTC1911985 1