PERFORMANCE OF THE SLD CENTRAL DRIFT CHAMBER

被引:7
作者
HILDRETH, MD
JUNK, TR
MARKIEWICZ, TW
MASUDA, H
MOURS, B
NEAL, HA
PRESCOTT, CY
ROCHESTER, LS
SUGIYAMA, A
TAKAHASHI, T
USHER, T
YOUNG, CC
SHYPIT, R
FERO, MJ
WILLIAMS, DC
MASSETTI, R
VENUTI, J
HONMA, A
机构
[1] UNIV BRITISH COLUMBIA,VANCOUVER,BC V6T 1Z1,CANADA
[2] MIT,CAMBRIDGE,MA 02139
[3] IST NAZL FIS NUCL,SEZ PERUGIA,I-06100 PERUGIA,ITALY
[4] UNIV PERUGIA,I-06100 PERUGIA,ITALY
[5] VANDERBILT UNIV,NASHVILLE,TN 37235
[6] UNIV VICTORIA,VICTORIA,BC V8W 3P6,CANADA
关键词
D O I
10.1109/23.467802
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report for the first time on the performance of the Central Drift Chamber (CDC) of the Stanford Linear Collider Large Detector (SLD), which has been recording data since 1992. The low mass of the chamber and the use of a gas characterized by both a low drift velocity and low diffusion constant help to minimize the drift-distance measurement errors. We describe some of the calibrations and corrections applied to the data, and report on the resolutions achieved thus far. We measure an intrinsic drift resolution of 55-110 mu m in the region of uniform field. Analysis of the full drift-pulse waveform allows for efficient double-hit resolution of about 1 mm. Momentum resolution is characterized by the formula (dp(t)/p(t)(2))(2) = 0.0050(2) + (0.010/p(t))(2), where p(t) is expressed in units of GeV/c. Used in conjunction with the SLD vertex detector, the CDC permits' measurements of impact parameters of high-momentum tracks to the level of 10 mu m in the r-phi plane rind 36 mu m in the r-z plane. A resolution of 6.4% is achieved in the measurement of dE/dx for the electrons in Bhabha scattering events.
引用
收藏
页码:451 / 458
页数:8
相关论文
共 8 条
[1]  
DAMERELL CJ, 1993, 26TH P INT C HIGH EN, P1862
[2]   PERFORMANCE REPORT FOR STANFORD SLAC MICROSTORE ANALOG MEMORY UNIT [J].
FREYTAG, DR ;
WALKER, JT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) :622-625
[3]   PHYSICAL PACKAGING AND ORGANIZATION OF THE DRIFT CHAMBER ELECTRONICS SYSTEM FOR THE STANFORD LARGE DETECTOR [J].
HALLER, GM ;
FREYTAG, ML ;
MAZAHERI, G ;
OLSEN, J ;
PAFFRATH, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :357-362
[4]   THE FRONT-END ANALOG AND DIGITAL SIGNAL-PROCESSING ELECTRONICS FOR THE DRIFT CHAMBERS OF THE STANFORD LARGE DETECTOR [J].
HALLER, GM ;
FREYTAG, DR ;
FOX, J ;
OLSEN, J ;
PAFFRATH, L ;
YIM, A ;
HONMA, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :363-369
[5]   PERFORMANCE OF THE FRONT-END SIGNAL-PROCESSING ELECTRONICS FOR THE DRIFT CHAMBERS OF THE STANFORD LARGE DETECTOR [J].
HONMA, A ;
HALLER, GM ;
USHER, T ;
SHYPIT, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :370-375
[6]   THE DIGITAL CORRECTION UNIT - A DATA CORRECTION-COMPACTION CHIP [J].
MACKENZIE, S ;
NIELSEN, B ;
PAFFRATH, L ;
RUSSELL, J ;
SHERDEN, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) :250-252
[7]   RADIATION AGING STUDIES OF CO2 HYDROCARBON MIXTURES FOR THE SLD DRIFT CHAMBER [J].
VENUTI, JP ;
CHADWICK, GB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :595-599
[8]   MICROSTORE - THE STANFORD ANALOG MEMORY UNIT [J].
WALKER, JT ;
CHAE, SI ;
SHAPIRO, S ;
LARSEN, RS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) :616-621