PRELIMINARY CLINICAL-TRIALS OF A COMPUTER-BASED CARDIAC-ARREST ALARM

被引:7
作者
CREW, AD
STOODLEY, KDC
LU, R
OLD, S
WARD, M
机构
[1] Yorkshire Regional Cardiothoracic Centre, Killingbeck Hospital, Leeds
关键词
COMPUTER ASSISTED SIGNAL PROCESSING; CRITICAL CARE; HEART ARREST; PHYSIOLOGICAL MONITORING;
D O I
10.1007/BF01716197
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The use of a high reliability cardiac arrest alarm utilising the continuously monitored values of patient heart rate and mean arterial blood pressure is described, based on a sample of 167 patients monitored for a total of 5116 h. The analogue heart rate and mean blood pressure signals are sampled at 1 s intervals, and a smoothing algorithm is applied to each of the resulting series which rejects artefacts, and identifies slope and step changes in each. Certain combinations of events in the 2 series, occurring within a preset time window, determine whether a cardiac arrest alarm of warning signal should be activated by the system. A total of 30 acute events occurring in 14 patients during the course of the study were each identified within 10 s. No cardiac arrest event was misdiagnosed by the algorithm during the period of the study. The algorithm also generates warnings which may have predictive value, and which will be the subject of further research. A final false alarm rate of about 1/200 h of monitoring was observed in adults (1/50 h in children), with evidence that these rates could be substantially improved.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 16 条
[1]  
BRYDON J, 1976, IEE MED ELECTRONICS, V18, P27
[2]   PRELIMINARY STUDIES IN THE IDENTIFICATION OF CARDIAC STATUS IN A CARDIAC SURGICAL INTENSIVE THERAPY UNIT [J].
CREW, AD ;
STOODLEY, KDC ;
NAGHDY, F ;
UNSWORTH, GD .
INTENSIVE CARE MEDICINE, 1984, 10 (02) :71-78
[3]  
ESCALONA O, 1986, Journal of Clinical Engineering, V11, P213
[4]  
Holt C.C, 1957, ONR MEMORANDUM NO 52
[5]   COMPUTED TREND ANALYSIS IN AUTOMATED PATIENT MONITORING SYSTEMS [J].
HOPE, CE ;
LEWIS, CD ;
PERRY, IR ;
GAMBLE, A .
BRITISH JOURNAL OF ANAESTHESIA, 1973, 45 (05) :440-449
[6]   CONVENTIONAL CORONARY-CARE UNIT MONITORING - NON-DETECTION OF TRANSIENT RHYTHM DISTURBANCES [J].
LINDSAY, J ;
BRUCKNER, NV .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1975, 232 (01) :51-53
[7]   ALARMS IN AN INTENSIVE CARE UNIT - AN INTERIM COMPROMISE [J].
RAISON, JCA ;
BEAUMONT, JO ;
RUSSELL, JAG ;
OSBORN, JJ ;
GERBODE, F .
COMPUTERS AND BIOMEDICAL RESEARCH, 1968, 1 (06) :556-&
[8]   UNRELIABILITY OF CONVENTIONAL ELECTROCARDIOGRAPHIC MONITORING FOR ARRHYTHMIA DETECTION IN CORONARY CARE UNITS [J].
ROMHILT, DW ;
BLOOMFIELD, SS ;
CHOU, TC ;
FOWLER, NO .
AMERICAN JOURNAL OF CARDIOLOGY, 1973, 31 (04) :457-461
[9]  
Safar P., 1981, CARDIOPULMONARY CERE
[10]  
SANDERS WJ, 1975, ALARM PROCESSING COM, P21