MOLECULAR PROFILING AND WEIGHT DETERMINATION OF HEPARINS AND DEPOLYMERIZED HEPARINS

被引:38
作者
AHSAN, A
JESKE, W
HOPPENSTEADT, D
LORMEAU, JC
WOLF, H
FAREED, J
机构
[1] LOYOLA UNIV,MED CTR,DEPT PHARMACOL,MAYWOOD,IL 60153
[2] SANOFI RECH,F-31036 TOULOUSE,FRANCE
[3] SANDOZ PHARMA AG,NURNBERG,GERMANY
关键词
D O I
10.1002/jps.2600840612
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The recently proposed calibrant LHN-1 (lot F537; henceforth designated F537), for the molecular weight (MW) determination by highperformance size-exclusion chromatography of heparins, is shown here to have a range too narrow to allow for the accurate MW determination of all low molecular weight heparins (LMWHs). We have recently demonstrated, by this same methodology, that a chemically degraded benzyl ester of unfractionated heparin, heparin mass calibrator (HMC), is a better calibrant. Weight-average MW, number-average MW, peak MW, and dispersity values were calculated with F537, HMC, and by a reference narrow-range-calibration method for various LMWHs and unfractionated heparins. Values for these parameters determined with HMC were not significantly different from those determined by the reference method until the MW of the substance exceeded 15.0 kDa. In contrast, the MW profile obtained with F537 was appreciably different from that obtained by the reference method for samples with MWs >7.5 kDa. The range exhibited by HMC should allow this calibrant to be used for both LMWHs and unfractionated heparins.
引用
收藏
页码:724 / 727
页数:4
相关论文
共 15 条
[1]   FEASIBILITY STUDY OF HEPARIN MASS CALIBRATOR AS A GPC CALIBRATOR FOR HEPARINS AND LOW-MOLECULAR-WEIGHT HEPARINS [J].
AHSAN, A ;
JESKE, W ;
MARDIGUIAN, J ;
FAREED, J .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (02) :197-201
[2]  
AHSAN A, 1993, SEMIN THROMB HEMOST, V19, P63
[3]  
BALKE ST, 1987, DETECTION DATA ANAL, P202
[4]   THE ANTICOAGULANT ACTIVITY OF HEPARIN - MEASUREMENT AND RELATIONSHIP TO CHEMICAL-STRUCTURE [J].
BARROWCLIFFE, TW ;
MULLOY, B ;
JOHNSON, EA ;
THOMAS, DP .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (02) :217-226
[5]   GRADIENT POLYACRYLAMIDE-GEL ELECTROPHORESIS FOR DETERMINATION OF MOLECULAR-WEIGHTS OF HEPARIN PREPARATIONS AND LOW-MOLECULAR-WEIGHT HEPARIN DERIVATIVES [J].
EDENS, RE ;
ALHAKIM, A ;
WEILER, JM ;
RETHWISCH, DG ;
FAREED, J ;
LINHARDT, RJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1992, 81 (08) :823-827
[6]  
EMANUELE RM, 1987, THESIS LOYOLA U MED
[7]   MOLECULAR-WEIGHT PROFILING OF LOW-MOLECULAR-WEIGHT HEPARINS UTILIZING A HEPARINASE DEGRADED OLIGOSACCHARIDE MIXTURE AS A CALIBRATOR [J].
JESKE, W ;
AHSAN, A ;
FAREED, J .
THROMBOSIS RESEARCH, 1993, 70 (01) :39-50
[8]   MOLECULAR-WEIGHT RANGE OF MUCOSAL-HEPARIN PREPARATIONS [J].
JOHNSON, EA ;
MULLOY, B .
CARBOHYDRATE RESEARCH, 1976, 51 (01) :119-127
[9]  
KUO C, 1987, DETECTION DATA ANAL, P2
[10]  
Lindahl, 1989, HEPARIN CHEM BIOL PR, P51