PERFORMANCE OF THE FORWARD RICH DETECTOR SYSTEM AT DELPHI

被引:5
作者
ADAM, W
ALBRECHT, E
AMBEC, I
AUGUSTINUS, A
BARNOUX, C
BOSTJANCIC, B
BOTNER, O
BUDZIAK, A
CARECHIO, P
CAVALLI, P
CEELIE, L
CERESETO, R
CERUTTI, G
DAHLJENSEN, E
DAM, P
DAMGAARD, G
DIMITRIOU, N
DULINSKI, W
EEK, LO
EKELOF, T
ERIKSON, J
FLOREK, A
FLOREK, B
FONTANELLI, F
FONTENILLE, A
GALUSZKA, K
GARCIA, J
GRACCO, V
HALLGREN, A
HAO, W
HENKES, T
ISENHOWER, D
JOHANSSON, H
KARVELAS, E
KINDBLOM, P
KOENE, B
DEKONING, N
KORPORAAL, A
KOSTARAKIS, P
LENZEN, G
LINDQVIST, LE
LORENZ, P
LOUKAS, D
LUNDJENSEN, B
MALTEZOS, A
MARKOU, A
MATTSSON, L
MEDBO, J
MICHALOWSKI, J
MONTANO, F
机构
[1] UNIV UPPSALA,DEPT RADIOL SCI,S-75105 UPPSALA,SWEDEN
[2] NATL INST NUCL PHYS & HIGH ENERGY PHYS,AMSTERDAM,NETHERLANDS
[3] UNIV GRENOBLE 1,INST SCI NUCL,F-38041 GRENOBLE,FRANCE
[4] INST JOZEF STEFAN,LJUBLJANA,SLOVENIA
[5] INST NUCL PHYS,PL-31342 KRAKOW,POLAND
[6] UNIV GENOA,DIPARTIMENTO FIS,I-16126 GENOA,ITALY
[7] INFN,GENOA,ITALY
[8] NIELS BOHR INST,COPENHAGEN,DENMARK
[9] NCSR DEMOCRITOS,ATHENS,GREECE
[10] COPPE,RIO JANEIRO,BRAZIL
[11] UNIV SANTANDER,SANTANDER,SPAIN
[12] UNIV GESAMTHSCH WUPPERTAL,FACHBEREICH PHYS,W-5600 WUPPERTAL 1,GERMANY
关键词
D O I
10.1109/23.256621
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
One quarter of the Forward Ring Imaging Cherenkov detector is installed and has been operated in the DELPHI experiment. The detector covers the forward-backward regions (15-degrees < theta < 35-degrees). Two radiator systems are used for particle identification in the momentum range up to 40 Gev/c, a liquid Perfluorohexane and the Perfluorobutane gas. UV-photons with wave lengths from approximately 170 nm to approximately 200 nm (7.3-6.2 eV) are detected with high efficiency. The total active area of the photon detector is approximately 8 m2.
引用
收藏
页码:583 / 588
页数:6
相关论文
共 15 条
[1]  
Aarnio P, 1991, NUCL INSTRUM METH A, V303, P233
[2]  
ADAM W, 1991, MAR CHEP C TSUK
[3]  
ADYE T, ARCHITECTURE PERFORM
[4]   AN IMPROVED METHOD FOR MANUFACTURING ACCURATE AND CHEAP GLASS PARABOLIC-MIRRORS [J].
BAILLON, P ;
BRAEM, A ;
GENDRE, G ;
MURATORI, G ;
NICHOLS, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 276 (03) :492-495
[5]  
BOSTJANCIC B, 1992, UNPUB NUCL INSTR M A
[6]  
BOTNER O, DELPHI887
[7]  
DAHLJENSEN E, 1992, MONTE CARLO FORWARD
[8]  
DAM P, 1992, IEEE NS, V39
[9]   THE LTD - A FASTBUS TIME DIGITIZER FOR LEP DETECTORS [J].
DELAVALLADE, G ;
VANUXEM, JP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3) :596-604
[10]   OPERATION OF RICH SINGLE-PHOTON DETECTORS WITH OPTICALLY SHIELDED WIRES IN TRANSVERSE MAGNETIC-FIELDS [J].
DULINSKI, W ;
EEK, LO ;
EKELOF, T ;
FRANSSON, K ;
HALLGREN, A ;
KOSTARAKIS, P ;
LENZEN, G ;
LORENZ, P ;
LUNDJENSEN, B ;
MICHALOWSKI, J ;
TURALA, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 252 (2-3) :418-422