BIOMECHANICAL ANALYSIS OF FACET AND GRAFT LOADING IN A SMITH-ROBINSON TYPE CERVICAL-SPINE MODEL

被引:61
作者
OLSEWSKI, JM [1 ]
GARVEY, TA [1 ]
SCHENDEL, MJ [1 ]
机构
[1] UNIV MINNESOTA,420 DELAWARE ST SE,BOX 289,UMHC,MINNEAPOLIS,MN 55455
关键词
DISTRACTION; CERVICAL; GRAFT LOADING; IN-VITRO; POSTERIOR ELEMENTS;
D O I
10.1097/00007632-199411001-00008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective. This study determined the effect of change in graft height on the forces across a Smith-Robinson graft as well as across the posterior elements of the same motion segment. Study Design. The study utilizes a strain gauge technique for the measurement of facet joint loading and a subminiature load cell for the measurement of graft loads. Summary of Background Data. A number of cases of Smith-Robinson procedures have had some form of collapse of the interspace and graft material after surgery. Some patients with collapse of the graft go on to have prolonged sclerotomal-type pain or pseudarthrosis. The appropriate amount of distraction is not well defined in the literature and may affect the outcome. Methods. Cervical spines (C5-C6) were instrumented by placing strain gauges bilaterally on the pedicles of C6 (to measure the forces across the posterior elements). A miniature load cell with matching metallic shims was used to measure the force across the graft site and to distract the segment. Forces across the posterior elements and the graft site were measured, during flexion loading, and compared as the disc space was distracted. Results. The ratio of posterior element load to graft load with increasing disc space distraction significantly decreased from 1.06 +/- 0.65 (1.4 mm distraction) to 0.30 +/- .13 (4.6 mm distraction) (P < .03). The posterior element load decreased significantly after the same distraction, from 46.1 +/- 22.0 to 18.7 +/- 9.7 N/Nm (P < .05). Conclusions. In spondylotic specimens (4-5 mm disc heights) disc space distraction in excess of 3.0 mm from preoperative height caused a significant decrease in both the ratio of posterior element to graft loading and posterior element loads. These findings may help explain recent clinical reports of a limit of effective disc space distraction.
引用
收藏
页码:2540 / 2544
页数:5
相关论文
共 32 条
[1]
An H.S., Evanich C.J., Nowicki B., Haughton V., Ideal Thickness of Smith-Robinson Graft for Anterior Cervical Fusion: A Cadaveric Study with CT Correlation, (1992)
[2]
Aronson N.I., The management of soft cervical disc protrusions using the Smith-Robinson approach, Clin Neurosurg, 20, pp. 253-258, (1973)
[3]
Aronson N., Bagan M., Filtzer D.L., Results of using the Smith-Robinson approach for herniated and extruded cervical discs, J Neurosurg, 32, pp. 721-722, (1970)
[4]
Aronson N., Filtzer D.L., Bagan M., Anterior cervical fusion by the Smith-Robinson approach, J Neurosurg, 29, pp. 397-404, (1968)
[5]
Bayley J.C., Yoo J.U., Zou D., Et al., The Role of Distraction in Improving the Space for the Cord and Nerve Roots in Cervical Spondylosis, (1991)
[6]
Bell D.G., Bailey S.I., Anterior cervical fusion for trauma, Clin Orthop Rel Res, 128, pp. 155-158, (1977)
[7]
Bremer A.M., Nguyen T.Q., Internal metal plate fixation combined with anterior interbody fusion in cases of cervical spine injury, J Neurosurg, 12, pp. 649-653, (1983)
[8]
Brower R.S., Herkowitz H.N., Kurz L. Effect of Distraction on the Union Rate of Smith-Robinson Type Anterior Cervical Discectomy and Fusion, (1992)
[9]
Buttermann G.R., Schendel M.J., Kahmann R.D., Lewis J.L., Bradford D.S., In vivo facet joint loading of the canine lumbar spine, Spine, 17, pp. 81-92, (1992)
[10]
Capen D.A., Garland D.E., Waters R.L., Surgical stabilization of the cervical spine, Clin Orthop Rel Res, 196, pp. 229-237, (1985)