EXTERNAL FIXATION OF UNSTABLE PELVIC RING FRACTURES - COMPARATIVE RIGIDITY OF SOME CURRENT FRAME CONFIGURATIONS

被引:31
作者
BROWN, TD
STONE, JP
SCHUSTER, JH
MEARS, DC
机构
[1] Dep. Orthop. Surg., Univ. Pittsburgh, Pittsburgh, PA 15261, United States
关键词
BIOMEDICAL ENGINEERING - Patient Treatment;
D O I
10.1007/BF02442527
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The effectiveness of external fixation in the stabilization of pelvic ring fractures was studied in a laboratory cadaveric series. Shearing displacements occurring at sacroiliac joint and symphysis pubis dislocation sites, due to simplified longitudinal loading of the sacrum in an lnstron unit, were monitored using variable-impedance transducers. The rigidity of fixation was compared for the Slatis and the Bonnel single anterior frames, for coupled and uncoupled double anterior frames, and for combined anterior-plus-posterior fixation achieved with separate transfixation pin clusters, with through-and-through pin clusters, or with a posterior screw plate. The data showed that the use of posterior fixation provided greatly enhanced stabilization compared to that achieved with anterior fixation alone. The complex double anterior frames performed only slightly better than did the simpler single anterior frames. In no case, however, was it possible to recover rigidity levels approaching those of the intact pelvis. The results suggest that the transfixation pin arrangement is the most important determinant of pelvic fixation stability, and that further investigation of posterior screw-plate fixation is warranted.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 9 条
[1]  
Carabalona P, 1973, MONTPELL CHIR, V19, P61
[2]  
CHAO EYS, 1980, P INT C FINITE ELEME, P691
[3]   FORCES ON PELVIS [J].
GOEL, VK ;
SVENSSON, NL .
JOURNAL OF BIOMECHANICS, 1977, 10 (03) :195-200
[4]   FIXATION OF PELVIC FRACTURES AND DISLOCATIONS - EXPERIMENTAL-STUDY ON LOADING OF PELVIC FRACTURES AND SACRO-ILIAC DISLOCATIONS AFTER EXTERNAL COMPRESSION FIXATION [J].
GUNTERBERG, B ;
GOLDIE, I ;
SLATIS, P .
ACTA ORTHOPAEDICA SCANDINAVICA, 1978, 49 (03) :278-286
[5]  
MCCOY MT, 1980, 26TH ANN ORS, P173
[6]  
MEARS DC, 1980, CLIN ORTHOP RELAT R, V151, P65
[7]  
MEARS DC, 1979, EXTERNAL FIXATION CU, pCH1
[8]  
NELSON DD, 1981, UNPUB 12TH P ANN M E
[9]   EXTERNAL FIXATION OF PELVIC GIRDLE WITH A TRAPEZOID COMPRESSION FRAME [J].
SLATIS, P ;
KARAHARJU, EO .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1975, 7 (01) :53-56