COMPARISON OF MAMMOGRAPHY, SONOGRAPHY, AND MAGNETIC-RESONANCE-IMAGING IN THE DETECTION OF SILICONE-GEL BREAST IMPLANT RUPTURE

被引:26
作者
REYNOLDS, HE
BUCKWALTER, KA
JACKSON, VP
SIWY, BK
ALEXANDER, SG
机构
[1] Department of Radiology, Indiana University Medical Center, Indiana University Hospital, Indianapolis, IN 46202
关键词
D O I
10.1097/00000637-199409000-00003
中图分类号
R61 [外科手术学];
学科分类号
摘要
Silicone-gel breast implant rupture is difficult to diagnose pre-operatively. A variety of radiological methods have been used for diagnosis. This study prospectively compares film-screen mammography, high-resolution sonography, and magnetic resonance imaging in the diagnosis of implant rupture using predetermined diagnostic criteria. Thirteen patients (24 implants) underwent film-screen mammography, sonography, and magnetic resonance imaging to evaluate the integrity of their implants. All patients subsequently underwent surgical removal of the implants. Preoperatively, the integrity of each implant was rated on a three-level classification system on the basis of one modality by a reviewer who was unaware of the results of the other two modalities. The three imaging modalities achieved the following sensitivities and specificities, respectively: mammography, 69% and 82%; sonography, 54% and 64%; MRI, 69% and 55%. Even though each modality addresses some of the limitations of the others, in this group of patients, there was no clearly superior imaging tool.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 14 条
[1]   EXUDATION OF SILICONE THROUGH THE ENVELOPE OF GEL-FILLED BREAST PROSTHESES - INVITRO STUDY [J].
BERGMAN, RB ;
VANDERENDE, AE .
BRITISH JOURNAL OF PLASTIC SURGERY, 1979, 32 (01) :31-34
[2]  
BREM RF, 1992, J COMPUT ASSIST TOMO, V16, P157
[3]   SILICONE BREAST IMPLANTS - US EVALUATION [J].
DEBRUHL, ND ;
GORCZYCA, DP ;
AHN, CY ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1993, 189 (01) :95-98
[4]   SILICONE BREAST IMPLANTS INVIVO - MR IMAGING [J].
GORCZYCA, DP ;
SINHA, S ;
AHN, CY ;
DEBRUHL, ND ;
HAYES, MK ;
GAUSCHE, VR ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1992, 185 (02) :407-410
[5]  
Harms Steven E., 1992, Magnetic Resonance Quarterly, V8, P139
[6]   SILICONE IMPLANT RUPTURE - DETECTION WITH US [J].
HARRIS, KM ;
GANOTT, MA ;
SHESTAK, KC ;
LOSKEN, HW ;
TOBON, H .
RADIOLOGY, 1993, 187 (03) :761-768
[7]   SILICONE GRANULOMAS - DETECTION BY ULTRASONOGRAPHY [J].
HERZOG, P .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 84 (05) :856-857
[8]   GD-DTPA ENHANCED MR IMAGING OF THE BREAST IN PATIENTS WITH POSTOPERATIVE SCARRING AND SILICON IMPLANTS [J].
HEYWANG, SH ;
HILBERTZ, T ;
BECK, R ;
BAUER, WM ;
EIERMANN, W ;
PERMANETTER, W .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) :348-356
[9]   DEFINITIVE DIAGNOSIS OF BREAST IMPLANT RUPTURE BY ULTRASONOGRAPHY [J].
LEVINE, RA ;
COLLINS, TL .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 87 (06) :1126-1128
[10]   RUPTURED GEL-FILLED SILICONE BREAST IMPLANTS - SONOGRAPHIC FINDINGS IN 19 CASES [J].
ROSCULET, KA ;
IKEDA, DM ;
FORREST, ME ;
ONEAL, RM ;
RUBIN, JM ;
JEFFRIES, DO ;
HELVIE, MA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (04) :711-716