USE OF THE EMITTOX SERUM TRICYCLIC ANTIDEPRESSANT ASSAY FOR THE ANALYSIS OF URINE SAMPLES

被引:6
作者
ASSELIN, WM
LESLIE, JM
机构
[1] Royal Canadian Mounted Police, Forensic Laboratory, Vancouver, BC, VSZ 3L7
关键词
D O I
10.1093/jat/14.3.168
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The EMITtox serum tricyclic antidepressant (TCA) assay is intended for use with serum or plasma. Currently, there are no commercially available immunoassay kits available for the detection of TCAs in urine. The proposed method utilizes the EMITtox serum TCA assay for the direct analysis of urine samples. The minimum detectable concentration of nortriptyline in urine is 25 ng/mL. The within-run CV was determined to be 0.6% and the between-run CV was 2.6%. The TCA assay cross-reacts with phenothiazines and antihistamines. The proposed methodology should be applicable to other EMIT serum assays to allow their use with urine. © 1990 Oxford University Press.
引用
收藏
页码:168 / 171
页数:4
相关论文
共 6 条
[1]  
ASSELIN WM, UNPUB
[2]   CLINICAL PHARMACOLOGICAL EVALUATION OF AN ASSAY KIT FOR INTOXICATIONS WITH TRICYCLIC ANTIDEPRESSANTS [J].
BENITEZ, J ;
DAHLQVIST, R ;
GUSTAFSSON, LL ;
MAGNUSSON, A ;
SJOQVIST, F .
THERAPEUTIC DRUG MONITORING, 1986, 8 (01) :102-105
[3]  
MOFFAT AC, 1986, CLARKES ISOLATION ID
[4]   EVALUATION OF SYVA EMIT TOXICOLOGICAL SERUM TRICYCLIC ANTIDEPRESSANT ASSAY [J].
SCHROEDER, TJ ;
TASSET, JJ ;
OTTEN, EJ ;
HEDGES, JR .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1986, 10 (06) :221-224
[5]  
SORISKY A, 1986, CLIN CHEM, V32, P715
[6]  
1987, SERUM TRICYCLIC ANTI