A modality-independent approach to spatial normalization of tomographic images of the human brain

被引:217
作者
Lancaster, JL
Glass, TG
Lankipalli, BR
Downs, H
Mayberg, H
Fox, PT
机构
[1] Research Imaging Center, University of Texas Health Science Center at San Antonio, San Antonio, Texas
关键词
spatial normalization; coordinate transformation; affine transformation; BrainMap; neuroscience databases; MRI; CT; PET; SPECT;
D O I
10.1002/hbm.460030305
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
A modality-independent approach for interactive spatial normalization of tomographic images of the human brain is described and its performance evaluated. Spatial normalization is accomplished using a nine-parameter affine transformation to interactively align and adjust the shape of a subject brain to the reference brain detailed in the 1988 atlas of Talairach et al. A user-friendly software application was developed using the X-windows Motif environment to guide the user through this process. This software supports data types from a wide variety of tomographic imagers and produces output in spatially concise formats. The parameters used for spatial alignment and shape normalization are presented and methods to apply them discussed. Where normalization parameters cannot be obtained directly from the image, as with positron emission tomography (PET), methods for estimating them are given. Evaluation of a new four-landmark method to fit the AC-PC Line in 16 magnetic resonance imaging (MRI) studies indicated an average difference assessed as the distance between the true and fitted AC-PC line at four locations of 0.82 mm when using a 2-D weighted fit. The same landmarks were evaluated using lower spatial resolution PET-like images simulated from the 16 MRI studies. The difference between the PET and MR image volumes following alignment was minimal, with mean rotational differences of less than 0.2 deg and mean translational differences of generally less than 2 mm. Spatial normalization is illustrated for single photon emission computed tomography (SPECT), X-ray computed tomography (CT), PET, and MR image volumes. Modality-independent spatial normalization can be consistently and reliably performed with the methods and software presented. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:209 / 223
页数:15
相关论文
共 34 条
[2]   HOUGH TRANSFORM DETECTION OF THE LONGITUDINAL FISSURE IN TOMOGRAPHIC HEAD IMAGES [J].
BRUMMER, ME .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (01) :74-87
[3]   AUTOMATIC 3D INTERSUBJECT REGISTRATION OF MR VOLUMETRIC DATA IN STANDARDIZED TALAIRACH SPACE [J].
COLLINS, DL ;
NEELIN, P ;
PETERS, TM ;
EVANS, AC .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (02) :192-205
[4]   Automatic 3-D model-based neuroanatomical segmentation [J].
Collins, DL ;
Holmes, CJ ;
Peters, TM ;
Evans, AC .
HUMAN BRAIN MAPPING, 1995, 3 (03) :190-208
[5]  
Downs JH, 1994, ADV FUNCTIONAL NEURO, P131
[6]  
EVANS AC, 1989, P SOC PHOTO-OPT INS, V1092, P264
[7]  
Fox P.T., 1994, FUNCTIONAL NEUROIMAG, P95
[8]   NEUROSCIENCE ON THE NET [J].
FOX, PT ;
LANCASTER, JL .
SCIENCE, 1994, 266 (5187) :994-996
[9]   A STEREOTACTIC METHOD OF ANATOMICAL LOCALIZATION FOR POSITRON EMISSION TOMOGRAPHY [J].
FOX, PT ;
PERLMUTTER, JS ;
RAICHLE, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (01) :141-153
[10]   COMPARING FUNCTIONAL (PET) IMAGES - THE ASSESSMENT OF SIGNIFICANT CHANGE [J].
FRISTON, KJ ;
FRITH, CD ;
LIDDLE, PF ;
FRACKOWIAK, RSJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1991, 11 (04) :690-699