IN-VIVO AND IN-VITRO ANALYSIS OF MEMBRANES FROM HIP PROSTHESES INSERTED WITHOUT CEMENT

被引:115
作者
KIM, KJ [1 ]
CHIBA, J [1 ]
RUBASH, HE [1 ]
机构
[1] UNIV PITTSBURGH, DEPT ORTHOPAED SURG, FERGUSON LAB, PITTSBURGH, PA USA
关键词
D O I
10.2106/00004623-199402000-00002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Biochemical, histological, and immunohistochemical studies of interface membranes surrounding failed hip prostheses that had been inserted without cement were done to examine specific factors involved in the development of aseptic loosening. Membranes from sixty-four femoral components were obtained from sixty-three patients during revision arthroplasty. Fifty-seven membranes were from implants that articulated with polyethylene (thirty-two were made of cobalt-chromium alloy and twenty-five, titanium alloy), and seven were from unipolar endoprostheses made of cobalt-chromium alloy that did not articulate with polyethylene. The membranes from implants with a polyethylene articulation produced significantly higher levels of collagenase and interleukin-1 (p < 0.05). However, there was no significant difference in the levels of prostaglandin E(2) between the three groups. Furthermore, membranes from implants with roentgenographic evidence of focal osteolysis (endosteal erosion) released significantly higher levels of interleukin-1 (p < 0.05) than did membranes from implants without focal osteolysis. Although the membranes from the titanium-alloy implants tended to contain more metal debris than those from the cobalt-chromium-alloy implants, the biochemical findings were not significantly different between these two groups. Many macrophages that were filled with polyethylene and metal debris were present in the membranes from both groups with a polyethylene articulation. Few T lymphocytes or B lymphocytes were identified in the three groups. CLINICAL RELEVANCE: This study demonstrates that macrophages activated by metal and polyethylene debris in interface membranes surrounding loosened femoral components that have been inserted without cement are a source of biochemical mediators of bone resorption. Such debris in these membranes may play an important role in the initiation of femoral osteolysis and the biochemical process of aseptic loosening of femoral implants inserted without cement. Additional studies are needed to characterize the size, shape, and origin of the debris found in these interface membranes.
引用
收藏
页码:172 / 180
页数:9
相关论文
共 32 条
[1]  
ADAMS DO, 1981, METHODS STUDYING MON, P136
[2]  
BENNETT NE, 1991, T ORTHOP RES SOC, V37, P188
[3]   OSTEOLYTIC CHANGES IN THE UPPER FEMORAL-SHAFT FOLLOWING POROUS-COATED HIP-REPLACEMENT [J].
BROWN, IW ;
RING, PA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1985, 67 (02) :218-221
[4]   EXCESSIVE METAL RELEASE DUE TO LOOSENING AND FRETTING OF SINTERED PARTICLES ON POROUS-COATED HIP PROSTHESES - REPORT OF 2 CASES [J].
BUCHERT, PK ;
VAUGHN, BK ;
MALLORY, TH ;
ENGH, CA ;
BOBYN, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (04) :606-609
[5]   THE UNCEMENTED POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS - 2-YEAR RESULTS OF A PROSPECTIVE CONSECUTIVE SERIES [J].
CALLAGHAN, JJ ;
DYSART, SH ;
SAVORY, CG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :337-346
[6]  
CHAMBERS TJ, 1985, CELL TISSUE RES, V241, P671
[7]  
CLARKE IC, 1983, ASTM STP, V796, P136
[8]  
DOIT LD, 1990, CLIN ORTHOP RELAT R, V261, P82
[9]  
Engh C. A., 1983, CLIN ORTHOP RELAT R, V176, P52
[10]   THE SYNOVIAL-LIKE MEMBRANE AT THE BONE-CEMENT INTERFACE IN LOOSE TOTAL HIP REPLACEMENTS AND ITS PROPOSED ROLE IN BONE LYSIS [J].
GOLDRING, SR ;
SCHILLER, AL ;
ROELKE, M ;
ROURKE, CM ;
ONEILL, DA ;
HARRIS, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (05) :575-584