LEVONORGESTREL INTRAUTERINE-DEVICE IN THE TREATMENT OF MENORRHAGIA IN CHINESE WOMEN - EFFICACY VERSUS ACCEPTABILITY

被引:40
作者
TANG, GWK
LO, SST
机构
[1] Department of Obstetrics and Gynaecology, University of Hong Kong
关键词
MENORRHAGIA; LEVONORGESTREL DEVICE; ACCEPTABILITY;
D O I
10.1016/0010-7824(95)00038-C
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Ten Chinese women who had menorrhagia without organic cause and suffered from anaemia were treated with levonorgestrel intrauterine device for a total of 129 woman-months. There was a 54%, 87% and 95% reduction in menstrual blood loss at the first, third and sixth month of treatment when compared with the pretreatment cycle. These percentages of reduction were statistically significant, with p values of 0.004, 0.03 and 0.008, respectively. There was a median increase in menstrual cycle length of 12 days in nine months. Fifteen percent of the menstrual cycles were longer than 60 days. The total bleeding days increased by 4 days at the third menstrual cycles, but reduced to a median of 6 days at 6 months. Seventy-six percent of the menstrual bleeding was in the form of spotting. These Chinese women accepted such menstrual alterations. There was no hormonal side effects. All women preferred the device to hysterectomy. Levonorgestrel intrauterine device appeared to be an effective and acceptable treatment for menorrhagia in perimenopausal Chinese women.
引用
收藏
页码:231 / 235
页数:5
相关论文
共 11 条
[1]   LEVONORGESTREL-RELEASING INTRAUTERINE-DEVICE IN THE TREATMENT OF MENORRHAGIA [J].
ANDERSSON, JK ;
RYBO, G .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (08) :690-694
[2]  
BAVEJA R, 1989, Contraception, V39, P37
[3]   DYSFUNCTIONAL UTERINE BLEEDING [J].
CAMERON, IT .
BAILLIERES CLINICAL OBSTETRICS AND GYNAECOLOGY, 1989, 3 (02) :315-327
[4]   COMPARISON BETWEEN MEFENAMIC-ACID AND DANAZOL IN THE TREATMENT OF ESTABLISHED MENORRHAGIA [J].
DOCKERAY, CJ ;
SHEPPARD, BL ;
BONNAR, J .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1989, 96 (07) :840-844
[5]   HYSTEROSCOPY FOR THE INVESTIGATION OF ABNORMAL UTERINE BLEEDING [J].
LEWIS, BV .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1990, 97 (04) :283-284
[6]   EFFECTIVE CONTRACEPTION WITH THE LEVONORGESTREL-RELEASING INTRAUTERINE-DEVICE - 12-MONTH REPORT OF A EUROPEAN MULTICENTER STUDY [J].
LUUKKAINEN, T ;
ALLONEN, H ;
HAUKKAMAA, M ;
HOLMA, P ;
PYORALA, T ;
TERHO, J ;
TOIVONEN, J ;
BATAR, I ;
LAMPE, L ;
ANDERSSON, K ;
ATTERFELDT, P ;
JOHANSSON, DB ;
NILSSON, S ;
NYGREN, KG ;
ODLIND, V ;
OLSSON, SE ;
RYBO, G ;
SIKSTROM, B ;
NIELSEN, NC ;
BUCH, A ;
OSLER, M ;
STEIER, A ;
ULSTEIN, M .
CONTRACEPTION, 1987, 36 (02) :169-179
[7]  
MACDONALD R, 1992, GYNAECOL ENDOSC, V1, P7
[8]  
MCPHERSON A, 1983, WOMENS PROBLEMS GENE, P70
[9]   A COMPARISON OF FLURBIPROFEN, TRANEXAMIC ACID, AND A LEVONORGESTREL-RELEASING INTRAUTERINE CONTRACEPTIVE DEVICE IN THE TREATMENT OF IDIOPATHIC MENORRHAGIA [J].
MILSOM, I ;
ANDERSSON, K ;
ANDERSCH, B ;
RYBO, G .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1991, 164 (03) :879-883
[10]   RAPID METHOD FOR MEASURING MENSTRUAL BLOOD-LOSS USING AUTOMATIC EXTRACTION [J].
NEWTON, J ;
BARNARD, G ;
COLLINS, W .
CONTRACEPTION, 1977, 16 (03) :269-282