FIELD-WEAKENING PERFORMANCE OF BRUSHLESS SYNCHRONOUS AC MOTOR-DRIVES

被引:353
作者
SOONG, WL [1 ]
MILLER, TJE [1 ]
机构
[1] UNIV GLASGOW,DEPT ELECT ENGN,GLASGOW G12 8LT,SCOTLAND
来源
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS | 1994年 / 141卷 / 06期
关键词
FIELD WEAKENING; FLUX WEAKENING; INTERIOR PERMANENT-MAGNET MOTOR; SYNCHRONOUS RELUCTANCE MOTOR; SURFACE PERMANENT-MAGNET MOTOR;
D O I
10.1049/ip-epa:19941470
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper examines the theoretical and practical limitations to the field-weakening performance of surface permanent magnet, synchronous reluctance and interior permanent magnet motors when driven from an inverter with a limited volt-ampere rating. It is shown that the 'optimal' field-weakening performance consists of an infinite constant-power speed range but is limited to an inverter utilisation of about 0.7. The new concept of the interior permanent magnet parameter plane is introduced. This graphically illustrates the effect of varying the drive parameters on the shape of the field-weakening characteristic. The interior permanent magnet parameter plane is used to show that there are three types of optimal field-weakening designs. When practical factors and considerations are taken into account, the optimal high-saliency interior permanent magnet motor design is the most promising for applications requiring a wide field-weakening range. A 7.5 kW design was built and a constant-power speed range exceeding 7.5:1 was demonstrated.
引用
收藏
页码:331 / 340
页数:10
相关论文
共 31 条