THE INFINITY CELL - A NEW TRAPPED-ION CELL WITH RADIOFREQUENCY COVERED TRAPPING ELECTRODES FOR FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE MASS-SPECTROMETRY

被引:389
作者
CARAVATTI, P
ALLEMANN, M
机构
[1] Spectrospin Ag, Fällanden
来源
ORGANIC MASS SPECTROMETRY | 1991年 / 26卷 / 05期
关键词
D O I
10.1002/oms.1210260527
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
The excitation event in Fourier transform ion cyclotron resonance mass spectrometry is optimized in order to obtain more reliable relative signal intensities and enhance the ion-selection performance in multi-tandem mass spectrometric experiments. Standard trapped-ion cells suffer from the undesirable ejection of ions along the symmetry axis (z-axis) of the cell, which is oriented parallel to the magnetic field lines. This z-ejection effect is difficult to predict, and thus difficult to avoid, especially when complicated broad-band excitation schemes are applied to the ions. An improved trapped-ion cell design, referred to as the 'Infinity Cell', is discussed which eliminates z-ejection. The Infinity Cell concept is based on the finding that it is possible to model the electric excitation field of an infinitely long cell with a cell of finite dimensions. The virtual elimination of z-ejection effects is demonstrated in several suitable experiments by comparing the operation of the standard cell and the Infinity Cell.
引用
收藏
页码:514 / 518
页数:5
相关论文
共 15 条
  • [1] EJECTION OF LOW-MASS CHARGED-PARTICLES IN HIGH MAGNETIC-FIELD ICR SPECTROMETERS
    ALLEMANN, M
    KOFEL, P
    KELLERHALS, H
    WANCZEK, KP
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1987, 75 (01): : 47 - 54
  • [2] A NEW FOURIER-TRANSFORM MASS-SPECTROMETER WITH A SUPERCONDUCTING MAGNET
    ALLEMANN, M
    KELLERHALS, H
    WANCZEK, KP
    [J]. CHEMICAL PHYSICS LETTERS, 1980, 75 (02) : 328 - 331
  • [3] BOGART TF, 1984, BASIC CONCEPTS LINEA
  • [4] CODY RB, 1985, ANAL CHIM ACTA, V178, P43
  • [5] FOURIER-TRANSFORM ION-CYCLOTRON RESONANCE SPECTROSCOPY
    COMISAROW, MB
    MARSHALL, AG
    [J]. CHEMICAL PHYSICS LETTERS, 1974, 25 (02) : 282 - 283
  • [6] DAHL DA, 1988, SIMION VERSION 40
  • [7] GROSSMANN P, 1988, 36TH P ANN C MASS SP, P616
  • [8] FIELD-CORRECTED ION CELL FOR ION-CYCLOTRON RESONANCE
    HANSON, CD
    CASTRO, ME
    KERLEY, EL
    RUSSELL, DH
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (05) : 520 - 526
  • [9] TANDEM QUADRUPOLE FOURIER-TRANSFORM MASS-SPECTROMETRY OF OLIGOPEPTIDES
    HUNT, DF
    SHABANOWITZ, J
    YATES, JR
    MCIVER, RT
    HUNTER, RL
    SYKA, JEP
    AMY, J
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (13) : 2728 - 2733
  • [10] EXTERNAL GENERATION OF IONS IN ICR SPECTROMETRY
    KOFEL, P
    ALLEMANN, M
    KELLERHALS, H
    WANCZEK, KP
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 65 (1-2): : 97 - 103