MR IMAGING OF THE PANCREAS AT HIGH-FIELD STRENGTH - COMPARISON OF 6 SEQUENCES

被引:36
作者
SEMELKA, RC
SIMM, FC
RECHT, MP
DEIMLING, M
LENZ, G
LAUB, GA
机构
[1] UNIV MANITOBA,WINNIPEG R3T 2N2,MANITOBA,CANADA
[2] SIEMENS AG,MED ENGN GRP,W-8520 ERLANGEN,GERMANY
关键词
PANCREAS; MAGNETIC RESONANCE IMAGING; TECHNIQUES; ARTIFACTS;
D O I
10.1097/00004728-199111000-00011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors compared six MR sequences comprising conventional breath-hold [rapid spin echo (RASE) repetition time (TR) 240 ms/echo time (TE) 8 ms/90-degrees, fast low angle shot (FLASH) 130/4.5/80-degrees, TurboFLASH 6.5/3.5/8-degrees], fat suppressed regular spin echo (FS SE 330/15/90-degrees), and two combined fat suppressed breath-hold sequences (FS FLASH 130/8/80-degrees, FS RASE 240/10/90-degrees) for studying the normal pancreas. Sequences were selected on the basis of features desirable for demonstrating the pancreas, particularly absence or decrease in artifacts and improved dynamic range of intraabdominal tissue signal intensities. Ten normal volunteers were studied, six at 1.5 T and four at 1.0 T, and comparison was made to regular short TR/TE SE. Quantitative pancreas signal-to-noise (S/N) and pancreas fat-to-noise (SD/N) measurements and qualitative evaluation of overall resolution and artifacts were determined. Fat suppressed FLASH had the highest SN (44.1 +/- 10.8, p < 0.0001) and SD/N (35.0 +/- 11.9, p < 0.0001), and seven studies were considered good or very good. Fat suppressed SE had good S/N (32.6 +/- 7.7) and SD/N (19.0 +/- 3.6), and eight FS SE studies were considered good or very good. Among the nonsuppressed sequences, FLASH had the best combination of quantitative and qualitative measurements. Our results suggest that fat suppression may be important for studying the pancreas and that nonsuppressed FLASH may be a reasonable alternative.
引用
收藏
页码:966 / 971
页数:6
相关论文
共 20 条
[1]   ISLET CELL TUMORS IN VONHIPPEL-LINDAU DISEASE - INCREASED PREVALENCE AND RELATIONSHIP TO THE MULTIPLE ENDOCRINE NEOPLASIAS [J].
BINKOVITZ, LA ;
JOHNSON, CD ;
STEPHENS, DH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (03) :501-505
[2]   DYNAMIC MR IMAGING OF THE LIVER WITH GD-DTPA - INITIAL CLINICAL-RESULTS [J].
EDELMAN, RR ;
SIEGEL, JB ;
SINGER, A ;
DUPUIS, K ;
LONGMAID, HE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) :1213-1219
[3]   DIAGNOSIS OF PANCREATIC TRANSPLANT DYSFUNCTION - VALUE OF GADOPENTETATE DIMEGLUMINE-ENHANCED MR IMAGING [J].
FERNANDEZ, MD ;
BERNARDINO, ME ;
NEYLAN, JF ;
OLSON, RA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (06) :1171-1176
[4]   GASTRINOMAS - COMPARISON OF MR IMAGING WITH CT, ANGIOGRAPHY, AND US [J].
FRUCHT, H ;
DOPPMAN, JL ;
NORTON, JA ;
MILLER, DL ;
DWYER, AJ ;
FRANK, JA ;
VINAYEK, R ;
MATON, PN ;
JENSEN, RT .
RADIOLOGY, 1989, 171 (03) :713-717
[5]   PANCREATIC ENHANCEMENT AFTER LOW-DOSE INFUSION OF MN-DPDP [J].
GEHL, HB ;
VORWERK, D ;
KLOSE, KC ;
GUNTHER, RW .
RADIOLOGY, 1991, 180 (02) :337-339
[6]   FERRITE PARTICLES FOR BOWEL CONTRAST IN MR IMAGING - DESIGN ISSUES AND FEASIBILITY STUDIES [J].
HAHN, PF ;
STARK, DD ;
SAINI, S ;
LEWIS, JM ;
WITTENBERG, J ;
FERRUCCI, JT .
RADIOLOGY, 1987, 164 (01) :37-41
[7]   THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING [J].
HOLSINGER, AE ;
RIEDERER, SJ .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) :481-488
[8]   MR IMAGING OF THE GASTROINTESTINAL-TRACT - VALUE OF GD-DTPA [J].
LANIADO, M ;
KORNMESSER, W ;
HAMM, B ;
CLAUSS, W ;
WEINMANN, HJ ;
FELIX, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (04) :817-821
[9]   PERFLUOROCHEMICALS AS GASTROINTESTINAL CONTRAST AGENTS FOR MR IMAGING - PRELIMINARY STUDIES IN RATS AND HUMANS [J].
MATTREY, RF ;
HAJEK, PC ;
GYLYSMORIN, VM ;
BAKER, LL ;
MARTIN, J ;
LONG, DC ;
LONG, DM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (06) :1259-1263