COMPARATIVE-STUDIES OF RECYCLING ISOELECTRIC-FOCUSING AND CONTINUOUS-FLOW ELECTROPHORESIS - SEPARATION OF PROTEINS WITH MINOR CHARGE DIFFERENCES

被引:10
作者
KNISLEY, KA
RODKEY, LS
机构
[1] UNIV TEXAS,SCH MED,DEPT PATHOL & LAB MED,POB 20708,HOUSTON,TX 77225
[2] TEXAS TECH UNIV,HLTH SCI CTR,DEPT CELL BIOL & ANAT,LUBBOCK,TX 79430
关键词
D O I
10.1002/elps.1150111108
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Continous flow zone electrophoresis (CFE) and recycling isoelectric focusing (RIEF) are two of the alternative formats for fluid phase preparative isolation of biological products in liquid separation media. The McDonnell Douglas CFE system has been used for both ground‐based and microgravity separations. The ground‐based McDonnell Douglas CFE and RIEF were compared for the ability to reslove mixtures of proteins with known charge differences. Mixtures of (1) cytochrome c, myoglobin, and ovalbumin or (2) beta‐lactoglobulin and ovalbumin were used to evaluate the resolving capabilities of CFE and RIEF. Following separation, fractions were analyzed by determining absorbance at 280 nm and by analytical isoelectric focusing (IEF) using Coomassie Brilliant Blue or silver staining to detect focused proteins. Both CFE and RIEF apparently separated the components of both mixtures into individual peaks, separated by fractions which contained little or no detectable protein. Coomassie‐stained analytical IEF gels supported this finding. However, when separated proteins were analyzed by silver staining of the analytical gels, the separation of ovalbumin from beta‐lactoglobulin by CFE was not complete. Ovalbumin was free ofbeta‐lactoglobulin but beta‐lactoglobulin was contaminated by trace amounts of ovalbumin. RIEF clearly separated each protein with no detectable contamination. These data demonstrate the superiority of RIEF over CFE for resolution of protein mixtures having only minor charge differences. RIEF may be more efficient due to the documented electrodissociation of noncovalent protein:protein complexes which occurs during RIEF separations. Copyright © 1990 VCH Verlagsgesellschaft mbH
引用
收藏
页码:927 / 931
页数:5
相关论文
共 8 条
[1]  
BIER M, 1979, PEPTIDES STRUCTURE B, V2, P79
[2]   SIMPLIFIED METHOD FOR SYNTHESIZING AMPHOLYTES SUITABLE FOR USE IN ISOELECTRIC-FOCUSING OF IMMUNOGLOBULINS IN AGAROSE GELS [J].
BINION, S ;
RODKEY, LS .
ANALYTICAL BIOCHEMISTRY, 1981, 112 (02) :362-366
[3]   CONTINUOUS-FLOW ELECTROPHORETIC SEPARATION OF PROTEINS AND CELLS FROM MAMMALIAN-TISSUES [J].
HYMER, WC ;
BARLOW, GH ;
BLAISDELL, SJ ;
CLEVELAND, C ;
FARRINGTON, MA ;
FELDMEIER, M ;
GRINDELAND, R ;
HATFIELD, JM ;
LANHAM, JW ;
LEWIS, ML ;
MORRISON, DR ;
OLACK, BJ ;
RICHMAN, DW ;
ROSE, J ;
SCHARP, DW ;
SNYDER, RS ;
SWANSON, CA ;
TODD, P ;
WILFINGER, W .
CELL BIOPHYSICS, 1987, 10 (01) :61-85
[4]  
KRUZEL ML, 1989, J BIOL REG HOMEOS AG, V3, P79
[5]   ISOELECTRIC-FOCUSING - A NEW APPROACH TO THE STUDY OF IMMUNE-COMPLEXES [J].
MAIDMENT, BW ;
PAPSIDERO, LD ;
CHU, TM .
JOURNAL OF IMMUNOLOGICAL METHODS, 1980, 35 (3-4) :297-306
[6]  
RODKEY LS, 1990, THEORET APPL ELECTRO, V1, P243
[7]   A new apparatus for electrophoretic analysis of colloidal mixtures. [J].
Tiselius, A .
TRANSACTIONS OF THE FARADAY SOCIETY, 1937, 33 (01) :0524-0530
[8]   PURIFICATION OF LENTIL LECTINS USING PREPARATIVE ELECTROPHORESIS [J].
WENGER, P ;
HEYDT, A ;
EGEN, NB ;
LONG, TD ;
BIER, M .
JOURNAL OF CHROMATOGRAPHY, 1988, 455 :225-239