MEG VERSUS EEG LOCALIZATION TEST USING IMPLANTED SOURCES IN THE HUMAN BRAIN

被引:227
作者
COHEN, D
CUFFIN, BN
YUNOKUCHI, K
MANIEWSKI, R
PURCELL, C
COSGROVE, GR
IVES, J
KENNEDY, JG
SCHOMER, DL
机构
[1] KAGOSHIMA UNIV,KAGOSHIMA 890,JAPAN
[2] POLISH ACAD SCI,WARSAW 42,POLAND
[3] BETH ISRAEL HOSP,DEPT SURG,BOSTON,MA 02215
[4] BETH ISRAEL HOSP,DEPT NEUROL,BOSTON,MA 02215
[5] DARTMOUTH COLL,HITCHCOCK MED CTR,DEPT NEUROSURG,HANOVER,NH 03756
关键词
D O I
10.1002/ana.410280613
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
It is believed that the magnetoencephalogram (MEG) localizes an electrical source in the brain to within several millimeters and is therefore more accurate than electroencephalogram (EEG) localization, reported as 20 mm. To test this belief, the localization accuracy of the MEG and EEG were directly compared. The signal source was a dipole at a known location in the brain; this was made by passing a weak current pulse simulating a neural signal through depth electrodes already implanted in patients for seizure monitoring. First, MEGs and EEGs from this dipole were measured at 16 places on the head. Then, computations were performed on the MEG and EEG data separately to determine the apparent MEG and EEG source locations. Finally, these were compared with the actual source location to determine the MEG and EEG localization errors. Measurements were made of four dipoles in each of three patients. After MEGs with weak signals were discounted, the MEG average error of localization was found to be 8 mm, which was worse than expected. The average EEG error was 10 mm, which was better than expected. These results suggest that the MEG offers no significant advantage over the EEG in localizing a focal source. However, this does not diminish other uses of the MEG. Copyright © 1990 American Neurological Association
引用
收藏
页码:811 / 817
页数:7
相关论文
共 27 条
[1]  
ATSUMI K, 1987, 6TH P INT C BIOM TOK
[2]   MAGNETIC LOCALIZATION OF A DIPOLAR CURRENT SOURCE IMPLANTED IN A SPHERE AND A HUMAN CRANIUM [J].
BARTH, DS ;
SUTHERLING, W ;
BROFFMAN, J ;
BEATTY, J .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1986, 63 (03) :260-273
[3]   THEORY OF MAGNETIC DETECTION OF HEARTS ELECTRICAL ACTIVITY [J].
BAULE, G ;
MCFEE, R .
JOURNAL OF APPLIED PHYSICS, 1965, 36 (06) :2066-&
[4]   DEMONSTRATION OF USEFUL DIFFERENCES BETWEEN MAGNETOENCEPHALOGRAM AND ELECTROENCEPHALOGRAM [J].
COHEN, D ;
CUFFIN, BN .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1983, 56 (01) :38-51
[5]  
COHEN D, 1987, ENCY NEUROSCIENCE, V2, P601
[7]   EFFECTS OF HEAD SHAPE ON EEGS AND MEGS [J].
CUFFIN, BN .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :44-52
[8]  
CUFFIN BN, 1991, IN PRESS ANN NEUROL
[9]   THE INVERSE PROBLEM - A MEDICAL PERSPECTIVE [J].
FENWICK, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (01) :5-9
[10]  
HAMALAINEN MS, 1985, BIOMAGNETISM APPLICA, P299