COMPARISON OF BONE INGROWTH INTO COBALT CHROME SPHERE AND TITANIUM FIBER MESH POROUS COATED CEMENTLESS CANINE ACETABULAR COMPONENTS

被引:44
作者
JASTY, M
BRAGDON, CR
HAIRE, T
MULROY, RD
HARRIS, WH
机构
[1] Orthopaedic Biomechanics Laboratory, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1993年 / 27卷 / 05期
关键词
D O I
10.1002/jbm.820270511
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Bone ingrowth into uncemented hemispherical canine acetabular components porous-coated with cobalt chrome spheres was compared to those porous-coated with titanium fiber mesh. While good bone ingrowth was noted in both types of porous coatings at 6 weeks after surgery with no difference in the histologic quality of the ingrown bone, quantitation of bone ingrowth showed that significantly more bone grew into titanium fiber mesh porous-coated components. The mean amount of bone ingrowth measured 10.5% of the area of the porous coating with fiber mesh coatings and only 5.5% of the area of the porous coating with spherical coatings (significant difference at P < .0005). The mean area density of the ingrown bone inside the pores measured 21.5% of the pore area with fiber mesh coatings, also significantly greater than 13.4% of the pore area with sphere coatings (P < .025). The ingrown bone penetrated a mean 66% of the depth of the porous layer with fiber mesh coatings compared to 32% of the depth of the porous layer with spherical coating (significant difference at P < .0005). The mean extent of the periphery of the porous layer with bone ingrowth was 88% for the mesh coatings and 55% for the spherical coatings (also a significant difference at P < .01).
引用
收藏
页码:639 / 644
页数:6
相关论文
共 16 条
[1]
BOBYN JD, 1980, CLIN ORTHOPAEDICS, V150, P263
[2]
THE UNCEMENTED POROUS-COATED ANATOMIC TOTAL HIP-PROSTHESIS - 2-YEAR RESULTS OF A PROSPECTIVE CONSECUTIVE SERIES [J].
CALLAGHAN, JJ ;
DYSART, SH ;
SAVORY, CG .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :337-346
[3]
CAMERON HU, 1978, INT J ARTIF ORGANS, V1, P104
[4]
DAVEY JR, 1988, CLIN ORTHOPAEDICS, V231, P97
[5]
DUCHEYNE P, 1978, J BIOMECH, V11, P297, DOI 10.1016/0021-9290(78)90063-5
[6]
Engh C. A., 1983, CLIN ORTHOP RELAT R, V176, P52
[7]
SINTERED FIBER METAL COMPOSITES AS A BASIS FOR ATTACHMENT OF IMPLANTS TO BONE [J].
GALANTE, J ;
ROSTOKER, W ;
LUECK, R ;
RAY, RD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (01) :101-&
[8]
HAMMAN G, 1987, ASTM STP, V953, P77
[9]
HARRIS WH, 1987, HIP, P214
[10]
HULBERT SF, 1973, J BIOMED MATER RES S, V4, P1