LARGE PARTICLE-SIZE DISTRIBUTION IN 5 UNITED-STATES CITIES AND THE EFFECT ON A NEW AMBIENT PARTICULATE MATTER STANDARD (PM10)

被引:21
作者
LUNDGREN, DA [1 ]
HAUSKNECHT, BJ [1 ]
BURTON, RM [1 ]
机构
[1] US EPA,EMSL,RES TRIANGLE PK,NC 27711
关键词
AEROSOLS - Sampling - PARTICLE SIZE ANALYSIS;
D O I
10.1080/02786828408959033
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A mobile aerosol-sampling system was used to determine the large particle ambient aerosol size distribution (up to approximately 100 mu m particle diameter) in five cities across the United States: Birmingham, Alabama; Research Triangle Park, North Carolina; Philadelphia, Pennsylvania; Phoenix, Arizona; and Riverside, California. A mobile wide range aerosol classifier (WRAC) developed at the University of Florida was used. The study shows that any measurement of ambient particulate matter with a size-fractionating inlet sampler will be influenced by the ambient particle size distribution. Mass distribution measurements determined by the WRAC were compared with mass measurements obtained simultaneously using TSP Hi-Vol and 15 mu m cut-size inhalable particulate network samplers. Aerosol size-classification results showed the presence of a large particle mass mode at all sites sampled.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 6 条
[1]   MASS-DISTRIBUTION OF LARGE ATMOSPHERIC PARTICLES [J].
LUNDGREN, DA ;
PAULUS, HJ .
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1975, 25 (12) :1227-1231
[2]  
LUNDGREN DA, 1982, PB82256264
[3]  
MCFARLAND AR, 1979, 86TH NAT M AM I CHEM
[4]  
VANDERPOOL R, 1983, THESIS U FLORIDA GAI
[5]   THE EFFECT OF SAMPLING INLETS ON THE PM-10 AND PM-15 TO TSP CONCENTRATION RATIOS [J].
WATSON, JG ;
CHOW, JC ;
SHAH, JJ ;
PACE, TG .
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1983, 33 (02) :114-119
[6]  
1983, 40CFR50 US GOVT