LOWRY PROTEIN ASSAY CONTAINING SODIUM DODECYL-SULFATE IN MICROTITER PLATES FOR PROTEIN DETERMINATIONS ON FRACTIONS FROM BRAIN-TISSUE

被引:75
作者
HARRINGTON, CR
机构
[1] Cambridge Brain Bank Laboratory, Department of Psychiatry, University of Cambridge School of Clinical Medicine, Cambridge, CB2 2QH, Hills Road
关键词
96-Well microtiter plate - Brain tissue - Microtiter plates - Modified lowry protein assays - Protein assays - Protein contents - Protein determination - Test samples;
D O I
10.1016/0003-2697(90)90081-J
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A modified Lowry protein assay which contains sodium dodecyl sulfate (Markwell et al., 1978, Anal. Biochem. 87, 207-210) has been adapted for use in 96-well microtiter plates. A spectrophotometer interfaced with a computer is used to plot the standard curve and calculate the protein content of each sample. The method is suitable for measuring 4-40 μg of protein/assay in a volume of 50 μl. There was no need for prior solubilization of proteins which had been extracted from brain tissue. Test samples, up to 21 in triplicate, can be tested on a single microtiter plate plus standards. Alternatively, further samples can be tested separately on extra plates using the standard curve from the original plate for calculations. © 1990.
引用
收藏
页码:285 / 287
页数:3
相关论文
共 13 条
  • [1] BRADFORD MM, 1976, ANAL BIOCHEM, V72, P248, DOI 10.1016/0003-2697(76)90527-3
  • [2] LOWRY PROTEIN ASSAY USING AN AUTOMATIC MICROTITER PLATE SPECTROPHOTOMETER
    FRYER, HJL
    DAVIS, GE
    MANTHORPE, M
    VARON, S
    [J]. ANALYTICAL BIOCHEMISTRY, 1986, 153 (02) : 262 - 266
  • [3] HARRINGTON CR, 1989, UNPUB
  • [4] KELLER RP, 1986, CLIN CHEM, V32, P120
  • [5] LOWRY OH, 1951, J BIOL CHEM, V193, P265
  • [6] Markwell M. A. K., 1978, ANAL BIOCHEM, V87, P207
  • [7] REVIEW OF THE FOLINE PHENOL PROTEIN QUANTITATION METHOD OF LOWRY, ROSEBROUGH, FARR AND RANDALL
    PETERSON, GL
    [J]. ANALYTICAL BIOCHEMISTRY, 1979, 100 (02) : 201 - 220
  • [8] ADAPTATION OF THE BICINCHONINIC ACID PROTEIN ASSAY FOR USE WITH MICROTITER PLATES AND SUCROSE GRADIENT FRACTIONS
    REDINBAUGH, MG
    TURLEY, RB
    [J]. ANALYTICAL BIOCHEMISTRY, 1986, 153 (02) : 267 - 271
  • [9] ADAPTATION OF THE DYE-BINDING PROTEIN ASSAY TO MICROTITER PLATES
    REDINBAUGH, MG
    CAMPBELL, WH
    [J]. ANALYTICAL BIOCHEMISTRY, 1985, 147 (01) : 144 - 147
  • [10] MEASUREMENT OF PROTEIN USING BICINCHONINIC ACID
    SMITH, PK
    KROHN, RI
    HERMANSON, GT
    MALLIA, AK
    GARTNER, FH
    PROVENZANO, MD
    FUJIMOTO, EK
    GOEKE, NM
    OLSON, BJ
    KLENK, DC
    [J]. ANALYTICAL BIOCHEMISTRY, 1985, 150 (01) : 76 - 85