A CONE-BEAM SPECT RECONSTRUCTION ALGORITHM WITH A DISPLACED CENTER OF ROTATION

被引:13
作者
LI, JY [1 ]
JASZCZAK, RJ [1 ]
WANG, HL [1 ]
GULLBERG, GT [1 ]
GREER, KL [1 ]
COLEMAN, RE [1 ]
机构
[1] UNIV UTAH,DEPT RADIOL,SALT LAKE CITY,UT 84132
关键词
SPECT; CONE BEAM; FILTERED BACKPROJECTION; CENTER OF ROTATION;
D O I
10.1118/1.597253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A filtered backprojection (FBP) algorithm is derived based on Feldkamp's FBP algorithm for a cone beam geometry that has a displaced center of rotation. In cone beam single photon emission computed tomography (CB-SPECT) the center of rotation displacement can degrade the reconstructed images. The center of rotation displacement of interest is mechanical shift, which is the displacement of the midplane of the cone beam collimator off the rotation center. Mechanical shift is characterized by two orthogonal components: the shift of the midplane of the cone beam collimator along the direction of the axis of rotation, and the distance between the midline of the cone beam collimator and the axis of rotation. This new algorithm corrects mechanical shift directly by incorporating mechanical shift into the algorithm. This new algorithm is evaluated using both Monte Carlo simulated data and experimentally acquired data. The results demonstrate that this algorithm is able to correct for blurring and the ''doughnut'' type artifacts caused by system mechanical shift and improve the image resolution.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 36 条
[1]  
BECK JW, 1982, IEEE T NUCL SCI, V29, P506, DOI 10.1109/TNS.1982.4335896
[2]   COMPENSATION OF TISSUE ABSORPTION IN EMISSION TOMOGRAPHY [J].
BELLINI, S ;
PIACENTINI, M ;
CAFFORIO, C ;
ROCCA, F .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1979, 27 (03) :213-218
[3]   3-DIMENSIONAL RECONSTRUCTION IN NUCLEAR-MEDICINE EMISSION IMAGING [J].
BUDINGER, TF ;
GULLBERG, GT .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (03) :2-20
[5]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[6]  
FLOYD CE, 1986, J NUCL MED, V27, P1577
[7]  
GRANGEAT P, 1991, SPIE, V1445, P320
[8]  
GREEN AJ, 1988, EUR J NUCL MED, V14, P226
[9]   ESTIMATION OF GEOMETRICAL PARAMETERS AND COLLIMATOR EVALUATION FOR CONE BEAM TOMOGRAPHY [J].
GULLBERG, GT ;
TSUI, BMW ;
CRAWFORD, CR ;
BALLARD, JG ;
HAGIUS, JT .
MEDICAL PHYSICS, 1990, 17 (02) :264-272
[10]   RECONSTRUCTION ALGORITHM FOR FAN BEAM WITH A DISPLACED CENTER-OF-ROTATION [J].
GULLBERG, GT ;
CRAWFORD, CR ;
TSUI, BMW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :23-29