RAPID, HIGH-RESOLUTION HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF ANTIBIOTICS

被引:20
作者
KIRKLAND, KM [1 ]
MCCOMBS, DA [1 ]
KIRKLAND, JJ [1 ]
机构
[1] ROCKLAND TECHNOL INC,NEWPORT,DE 19804
关键词
D O I
10.1016/0021-9673(94)85128-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A HPLC column devised for high separation speed combined with highly practical operating features has been found useful for separating antibiotics. Important characteristics involve compromises in packing particle size, column configuration and support-stationary phase combinations. We determined that these columns are useful for rapid, high-resolution separations with unmodified state-of-the-art HPLC equipment without the extra-column band-broadening effects typical of so-called ''fast'' HPLC columns. The proposed columns feature efficient sterically-protected monofunctional silane stationary phases that provide good separation reproducibility and high column stability. The combination of these unique bonded silanes and a highly purified, less-acidic silica support give superior peak shapes for antibiotic compounds. The proposed column configuration can halve separation times and double peak heights without loss in resolution, compared to widely used analytical columns. Increased mobile phase flow-rates permit even faster separations of antibiotics with only modest loss in resolution and peak heights for trace analyses in biological systems.
引用
收藏
页码:327 / 337
页数:11
相关论文
共 24 条
[1]  
BORNER K, 1990, ANAL DRUGS METABOLIT, P131
[2]   RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF CEPHALOSPORINS IN BIOLOGICAL-FLUIDS [J].
CHAN, CY ;
CHAN, K ;
FRENCH, GL .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1986, 18 (04) :537-545
[3]   COMPARISON OF 3-MICROMETER AND 5-MICROMETER COLUMN PACKINGS FOR REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
COOKE, NHC ;
ARCHER, BG ;
OLSEN, K ;
BERICK, A .
ANALYTICAL CHEMISTRY, 1982, 54 (13) :2277-2283
[4]  
Giddings J., 1965, DYNAMICS CHROMATOGRA
[5]  
GLAJCH JL, 1987, Patent No. 4705725
[6]  
HORVATH C, 1977, J CHROMATOGR, V149, P43
[7]   ROLE OF COLUMN PARAMETERS AND INJECTION VOLUME ON DETECTION LIMITS IN LIQUID-CHROMATOGRAPHY [J].
KARGER, BL ;
MARTIN, M ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1974, 46 (12) :1640-1647
[8]  
Kirkland J.J., 1974, United States Patent, Patent No. [3782075, 3,782,075]
[9]  
Kirkland J. J., 1988, ANAL CHEM, V61, P2
[10]   PREFERRED EXPERIMENTAL CONDITIONS FOR TRACE ANALYSIS BY MODERN LIQUID-CHROMATOGRAPHY [J].
KIRKLAND, JJ .
ANALYST, 1974, 99 (1185) :859-885