ASSESSMENT OF THE PERFORMANCE OF RESPIRATORS IN THE WORKPLACE

被引:6
作者
HERY, M
VILLA, M
HUBERT, G
MARTIN, P
机构
[1] Institut National de Recherche et de Sécurité, 54501 Vandoeuvre-les-Nancy Cédex, Avenue de Bourgogne
关键词
Gas Masks - Lead Compounds - Pigments - Manufacture - Powders - Manufacture - Zinc Compounds;
D O I
10.1093/annhyg/35.2.181
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The efficiency of a mask currently used in an inorganic pigment manufacturing plant producing suspected carcinogens was assessed and the protection provided by it was found to be insufficient. Three other masks, with better laboratory performances, were tested in field conditions. None of them reduced personal exposures to below the French limit values, and their performance in the field was well below that in laboratory assessments. A similar study in another pigment manufacturing plant gave similar results. Possibly only power-assisted filtering devices will provide satisfactory working conditions.
引用
收藏
页码:181 / 187
页数:7
相关论文
共 6 条
[1]   EFFECT OF RESPIRATORY PROTECTIVE EQUIPMENT ON EXPOSURE TO ASBESTOS FIBERS DURING REMOVAL OF ASBESTOS INSULATION [J].
AKKERSDIJK, H ;
BREMMER, CF ;
SCHLISZKA, C ;
SPEE, T .
ANNALS OF OCCUPATIONAL HYGIENE, 1989, 33 (01) :113-116
[2]   A COMPARISON OF AEROSOL SAMPLING TECHNIQUES - OPEN VERSUS CLOSED-FACE FILTER CASSETTES [J].
BEAULIEU, HJ ;
FIDINO, AV ;
ARLINGTON, KLB ;
BUCHAN, RM .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1980, 41 (10) :758-765
[3]   RESPIRATOR EVALUATION FOR CARBON SETTERS WITH BEARDS [J].
FERFIN, GS .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1984, 45 (08) :533-537
[4]  
HAGUENOER JM, 1981, OCCUPATIONAL SAFETY, V46, P168
[5]  
1987, MASQUES ANTIPOUSSIER
[6]  
1983, AFNORS76015 ASS FRAN