EXAMINATION OF RECOMBINANT TRUNCATED MATURE HUMAN FIBROBLAST COLLAGENASE BY MASS-SPECTROMETRY - IDENTIFICATION OF DIFFERENCES WITH THE PUBLISHED SEQUENCE AND DETERMINATION OF STABLE-ISOTOPE INCORPORATION

被引:3
作者
CHOWDHURY, SK
VAVRA, KJ
BRAKE, PG
BANKS, T
FALVO, J
WAHL, R
ESHRAGHI, J
GONVEA, G
CHAIT, BT
VESTAL, CH
机构
[1] VESTEC CORP, MASS SPECTROMETRY PROD, PERSEPT BIOSYST, HOUSTON, TX 77054 USA
[2] EASTMAN KODAK CO, LIFE SCI RES LABS, ROCHESTER, NY 14650 USA
[3] ROCKEFELLER UNIV, NEW YORK, NY 10021 USA
关键词
D O I
10.1002/rcm.1290090704
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Human fibroblast collagenase belongs to a family of matrix metalloproteinases which have been implicated in a number of connective tissue disorders ranging from rheumatoid arthritis to tumor invasion. To examine the active site of this enzyme by biophysical studies, a 19 kDa recombinant truncated mature collagenase (mCL-t) was prepared. Electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry have been utilized for the characterization of mCL-t. The molecular weights measured by these techniques identified the presence of two closely related protein components separated by approximately 100 Da. Edman sequence analysis demonstrated that the two protein components differ from each other by an amino terminal valine, consistent with the mass spectrometric data. In addition, the molecular weight of mCL-t determined by mass spectrometry did not agree with that calculated from the reported sequence. To identify the origin of this discrepancy, the DNA sequence of the mCL-t clone was examined. Several differences were noted between the DNA sequence of mCL-t and the published collagenase gene sequence. When these differences were taken into account, the measured molecular weights were found to be in good agreement with that calculated for the modified sequence. In separate experiments, both ESI and MALDI mass spectrometry have been used to determine molecular weights of mCL-t samples enriched with stable isotopes N-15 and (N-15 + C-13). The measured molecular weights demonstrated a 97% (N-15) and 99% (N-15 + C-13) incorporation of labeled isotopes in the two samples.
引用
收藏
页码:563 / 569
页数:7
相关论文
共 24 条
[1]  
Beavis R C, 1989, Rapid Commun Mass Spectrom, V3, P233, DOI 10.1002/rcm.1290030708
[2]   MONOCLONAL-ANTIBODIES TO HUMAN FIBROBLAST PROCOLLAGENASE - INHIBITION OF ENZYMATIC-ACTIVITY, AFFINITY PURIFICATION OF THE ENZYME, AND EVIDENCE FOR CLUSTERING OF EPITOPES IN THE NH2-TERMINAL END OF THE ACTIVATED ENZYME [J].
BIRKEDALHANSEN, B ;
MOORE, WGI ;
TAYLOR, RE ;
BHOWN, AS ;
BIRKEDALHANSEN, H .
BIOCHEMISTRY, 1988, 27 (18) :6751-6758
[3]   WEIGHING NAKED PROTEINS - PRACTICAL, HIGH-ACCURACY MASS MEASUREMENT OF PEPTIDES AND PROTEINS [J].
CHAIT, BT ;
KENT, SBH .
SCIENCE, 1992, 257 (5078) :1885-1894
[4]   AN ELECTROSPRAY-IONIZATION MASS-SPECTROMETER WITH NEW FEATURES [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (03) :81-87
[5]   FRAGMENTS OF HUMAN FIBROBLAST COLLAGENASE - PURIFICATION AND CHARACTERIZATION [J].
CLARK, IM ;
CAWSTON, TE .
BIOCHEMICAL JOURNAL, 1989, 263 (01) :201-206
[6]  
Covey T R, 1988, Rapid Commun Mass Spectrom, V2, P249, DOI 10.1002/rcm.1290021111
[7]   FACTORS AFFECTING ELECTROSPRAY-IONIZATION OF EFFLUENTS CONTAINING TRIFLUOROACETIC-ACID FOR HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY [J].
ESHRAGHI, J ;
CHOWDHURY, SK .
ANALYTICAL CHEMISTRY, 1993, 65 (23) :3528-3533
[8]  
EVANS CH, 1991, DRUGS INFLAMMATION
[9]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[10]  
GOLDBERG GI, 1986, J BIOL CHEM, V261, P6600