HIGH-OUTPUT CARDIAC-FAILURE DUE TO EXCESSIVE SHUNTING IN A HEMODIALYSIS ACCESS FISTULA - AN EASILY OVERLOOKED DIAGNOSIS

被引:107
作者
ENGELBERTS, I [1 ]
TORDOIR, JHM [1 ]
BOON, ES [1 ]
SCHREIJ, G [1 ]
机构
[1] ACAD HOSP MAASTRICHT,DEPT INTENS CARE MED,6202 AZ MAASTRICHT,NETHERLANDS
关键词
ARTERIOVENOUS HEMODIALYSIS ACCESS FISTULA; EXCESSIVE SHUNTING; HIGH-OUTPUT CARDIAC FAILURE; DIAGNOSIS; NONINVASIVE EVALUATION;
D O I
10.1159/000168857
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
A dialysis arteriovenous fistula caused life-threatening high-output cardiac failure in a 66-year-old patient. Excessive shunting through the dialysis fistula was demonstrated by invasive measurement of cardiac output, systemic arterial blood pressure, systemic vascular resistance, and oxygen consumption before and after temporary occlusion of the dialysis fistula. Noninvasive echocardiographic evaluation of the influence of fistula compression on cardiac output and noninvasive duplex measurement of the fistula flow also confirmed the diagnosis, Following surgical closure of the fistula, the patient's condition improved, and signs of congestive heart failure subsided. High-output cardiac failure is a rare complication of dialysis arteriovenous fistulas. The diagnosis may remain unrecognized for longer periods. Noninvasive methods for estimation of the hemodynamic importance of a fistula may be of help in the establishment of the proper diagnosis.
引用
收藏
页码:323 / 326
页数:4
相关论文
共 14 条
[1]   CARDIAC-FAILURE AND UPPER EXTREMITY ARTERIOVENOUS DIALYSIS FISTULAS - CASE-REPORTS AND A REVIEW OF LITERATURE [J].
ANDERSON, CB ;
CODD, JR ;
GRAFF, RA ;
GROCE, MA ;
HARTER, HR ;
NEWTON, WT .
ARCHIVES OF INTERNAL MEDICINE, 1976, 136 (03) :292-297
[2]  
BRESCIA MJ, 1966, NEW ENGL J MED, V775, P1089
[3]   CARDIAC-OUTPUT BY THERMODILUTION TECHNIQUE - EFFECT OF INJECTATES VOLUME AND TEMPERATURE ON ACCURACY AND REPRODUCIBILITY IN THE CRITICALLY ILL PATIENT [J].
ELKAYAM, U ;
BERKLEY, R ;
AZEN, S ;
WEBER, L ;
GEVA, B ;
HENRY, WL .
CHEST, 1983, 84 (04) :418-422
[4]   PROXIMAL FOREARM FISTULA FOR MAINTENANCE HEMODIALYSIS [J].
GRACZ, KC ;
ING, TS ;
SOUNG, LS ;
ARMBRUSTER, KFW ;
SEIM, SK ;
MERKEL, FK .
KIDNEY INTERNATIONAL, 1977, 11 (01) :71-74
[5]  
HAIMOV M, 1975, ARCH SURG-CHICAGO, V110, P708
[6]   HEMODYNAMIC EFFECTS OF ARTERIOVENOUS SHUNTS USED FOR HEMODIALYSIS [J].
JOHNSON, G ;
BLYTHE, WM .
ANNALS OF SURGERY, 1970, 171 (05) :715-+
[7]  
KATHREIN H, 1991, DUPLEX SONOGRAPHIE D, P45
[8]  
Leunissen KML, 1993, KIDNEY INT S, V43, P50
[9]   NEUROVASCULAR COMPLICATIONS OF BRACHIAL ARTERIOVENOUS FISTULA [J].
MATOLO, N ;
KASTAGIR, B ;
STEVENS, LE ;
CHRYSANTHAKOPOULOS, S ;
WEAVER, DH ;
KLINKMAN, H .
AMERICAN JOURNAL OF SURGERY, 1971, 121 (06) :716-+
[10]   FLOW OF DIALYSIS FISTULAS - NONINVASIVE STUDY PERFORMED WITH STANDARD DOPPLER EQUIPMENT [J].
MORAN, MR ;
RODRIGUEZ, JMR ;
BOYERO, MR ;
ENRIQUEZ, AA ;
MORIN, AI .
NEPHRON, 1985, 40 (01) :63-66